CES-AR-C01-EH-SA (Order no. 098582)
Safety switch CES-AR-C01-..., RFID, plug connector M12
- Fixcode evaluation
- Door position monitoring output OUT
- Plug connector M12, 8-pin

Description
Approach direction and installation position
1 active face, can be repositioned in 5 directions
Typical actuating ranges
With actuators CES-A-BBA and CES-A-BCA
For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm must be maintained so that the actuating range of the side lobes is not entered.
With actuator CES-A-BPA
For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the actuating range of the side lobes is not entered.
Attention:
The actuating range may vary depending on the actuator, substrate material and installation situation. You can find additional actuating ranges in the operating instructions.
Fixcode evaluation
An actuator included is permanently assigned to the switch. The switch can be operated only with this actuator. The actuator is taught-in at EUCHNER prior to delivery. No additional actuators can be taught in.
The system possesses a high coding level.
Safety characteristics
Due to two redundantly designed safety outputs (semiconductor outputs) with internal monitoring, the device is suitable for:
- Category 4 /PL e according to EN 13849-1
- SIL 3 according to EN IEC 62061 Table 4
The OSSD outputs used check their function for short circuits using test pulses.
LED indicator
STATE | Status LED |
DIA | Diagnostics LED |
Terminal assignment
Plug connector aligned C01
Plug connector in can be adjusted in 6 orientations.
Scope of delivery
- 2 x M5x10 safety screws
- Actuator CES-A-BPA-098775



Dimensional drawings

Dimensional drawings

| 1 | Active face |
Connection examples

Technical data
Approvals


Workspace
| Repeat accuracy R | |
| according to EN 60947-5-2 | 10 % |
Electrical connection values
| Fuse | |
| external (operating voltage) | 0.25 ... 8 A |
| Rated insulation voltage Ui | 75 V (Tested up to 75 V by employers' liability insurance association) |
| Rated impulse voltage Uimp | 1.5 kV |
| Operating voltage DC | |
| UB | 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV |
| Turn-on time | |
| Safety outputs | max. 400 ms |
| EMC protection requirements | Acc. to EN IEC 60947-5-3 |
| Risk time according to EN 60947-5-3 | max. 260 ms |
| Risk time according to EN 60947-5-3, extension for each additional device | max. 5 ms |
| Safety class | III |
| Current consumption | |
| no load on outputs | max. 50 mA |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| Monitoring output OUT | |
| Output type | p-switching, short circuit-proof |
| Output voltage | 0.8 x UB ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.) |
| Switching current | max. 200 mA |
| Safety outputs OA / OB | |
| Output type | Semiconductor outputs, p-switching, short circuit-proof |
| Output voltage | |
| LOW U(OA,OB) | 0 ... 1 V DC |
| HIGH U(OA,OB) | UB-1.5 ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.) |
| rated conditional short-circuit current | 100 A |
| Discrepancy time | max. 10 ms |
| Utilization category | |
| DC-13 | 24V 400mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
| Off-state current Ir | max. 0.25 mA |
| Switching current | |
| per safety output | 1 ... 400 mA |
| Test pulse duration | max. 1 ms |
Mechanical values and environment
| Connection type | M12 plug connector, 8-pin |
| Tightening torque | |
| Fixing screws | max. 1 Nm |
| Ready delay | 10 s |
| Installation orientation | any |
| Switching frequency | max. 1 Hz |
| Storage temperature | -25 ... 70 °C |
| Mounting distance | min. 40 mm |
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
| Degree of protection | IP67 |
| Ambient temperature | -20 ... 55 °C |
| Material | |
| Housing | Plastic, PBT |
Miscellaneous
| Notices for UL approval | Operation only with UL Class 2 power supply or equivalent measures |
Actuator CES-A-BPA-098775 (Order no. 098775)
Workspace
| Actuator distance s | |
| Minimum distance for side approach direction | min. 6 mm |
| Switch-on distance | |
| with center offset m=0 | 22 mm (for surface mounting of the actuator on metal) |
| Secured switch-off distance sar | |
| with center offset m=0 | 58 mm (for surface mounting of the actuator on metal) |
| Secured switching distance sao | |
| with center offset m=0 | min. 18 mm (for surface mounting of the actuator on metal) |
| Switching hysteresis | |
| with center offset m=0 | 1 ... 2 mm (for surface mounting of the actuator on metal) |
Electrical connection values
| Power supply | Inductive via read head |
Mechanical values and environment
| Tightening torque | |
| Fixing screws | max. 1 Nm |
| Storage temperature | -25 ... 70 °C |
| Degree of protection | IP65/IP67/IP69/IP69K |
| Ambient temperature | -25 ... 70 °C |
| Material | |
| Housing | Plastic (PBT) |
Components included in the set
| Included accessories | 2x safety screws M5x10 |
In combination with actuator CES-A-BPA-098775
| Switch-on distance | 22 mm (on surface mounting on aluminum. In a non-metallic environment, the typical operating distances increase to 30 mm) |
| Secured switch-off distance sar | 58 mm |
| Secured switching distance sao | min. 18 mm |
| Switching hysteresis | 1 ... 2 mm |
Accessories

AC-YD-V0,2-SBB-111696
- For the series connection of AR/BR safety switches in switch chains
- Y-distributor M12 with connecting cable, 2 x 5-pin, 1 x 8-pin
- Straight plug connector
- PVC cable
- Cable length 0.2 m

AC-YD-V1,0-SBB-112395
- For the series connection of AR/BR safety switches in switch chains
- Y-distributor M12 with connecting cable, 2 x 5-pin, 1 x 8-pin
- Straight plug connector
- PVC cable
- Cable length 1 m
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Other Documents
ePlan macros
Ordering data
| Ordernumber | 098582 |
| Item designation | CES-AR-C01-EH-SA |
| Gross weight | 0,22kg |
| Customs tariff number | 85365019000 |
| ECLASS | 27-27-24-03 Safety-related transponder switch |