MGB2-L2HE-BR-U-S0-DY-L-164385 (Order no. 164385)
									Choose content
									
									
									
									
									
									
									
									
									
									Complete set MGB2-L2HE-BR (2 pushbuttons, emergency stop, with escape release, open-circuit current principle, door hinge on left)
- Guard locking with guard lock monitoring
 - Emergency stop according to ISO 13850
 - 2 illuminated pushbuttons
 - 3 adhesive labels
 - Cable entry M20 x 1.5 (order cable gland separately)
 - Adjustable door hinge; factory setting: left
 - Unicode
 - incl. escape release and inner door handle
 

Description
Guard locking type
MGB2-L2...  | Guard locking by solenoid force. Activation of guard locking by applying voltage to the guard locking solenoid. (open-circuit current principle)  | 
Flexible adaptation through configuration
- The evaluation module can be configured with the aid of DIP switches. Depending on the setting, the evaluation module behaves like an MGB2-BP or an MGB2-BR device.
 
- In addition, guard lock monitoring can be switched on or off on devices with guard locking. When guard lock monitoring is switched on, the safe outputs are switched on if the guard is safely locked. When guard lock monitoring is switched off, the safe outputs are switched on if the guard is closed and the bolt tongue is inserted into the MGB2.
 
- Release monitoring can be activated when guard lock monitoring is switched on. This signals whether the auxiliary release or escape release was actuated.
 
- Factor reset permits resetting to the factory setting.
 
Lens set
The color of the pushbuttons can be selected using the lens set 120344 included (5 colors).
Adhesive labels
The user can produce custom labeling using the enclosed adhesive labels. (3 pcs., blank)
Escape release
It is used for manual release of the guard locking without tools in an emergency. The inner door handle permits escape from the danger zone.


Dimensional drawings

Dimensional drawings

Technical data
Approvals


Escape release MGB-E-A-100465 (Order no. 100465)
    Mechanical values and environment
| Installation orientation | any | 
| Mechanical life | 1 x 10⁶ | 
| Ambient temperature | -30 ... 55 °C | 
| Material | |
| Housing | Die-cast zinc/stainless steel, powder-coated | 
Miscellaneous
| Product version number | V2.0.0 | 
Locking modules MGB2-L2-BR-U-XB2S0-DY-L-164387 (Order no. 164387)
    Mechanical values and environment
| Installation orientation | Door hinge DIN left | 
Handle modules MGB2-H-BA1A1-L-156396 (Order no. 156396)
    Mechanical values and environment
| Installation orientation | Door hinge DIN left | 
| Degree of protection | IP65 | 
| Ambient temperature | -30 ... 55 °C | 
| Material | |
| Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel | 
Submodules MSM-1-K-CA-CPP-B2-137732
    Operating and display elements
| Item | Color | Extras | Version | Slide-in label | Note slide-in label | Switching element | Number | Designation1 | LED | 
|---|---|---|---|---|---|---|---|---|---|
| 1 | Emergency stop with monitoring contact | 2 PD + 1 NO | |||||||
| 2 | Illuminated pushbutton | 1NO | |||||||
| 3 | Illuminated pushbutton | 1NO | 
Electrical connection values
| Current consumption | max. 24 mA | 
| Controls and indicators | |
| Breaking capacity | max. 0.25 W | 
| Switching voltage | 24 V | 
| Switching current | 5 ... 10 mA | 
| LED power supply | 24 V DC | 
| Emergency stop | |
| Breaking capacity | max. 0.25 W | 
| Switching voltage | 5 ... 24 V | 
| Switching current | 1 ... 100 mA | 
Mechanical values and environment
| Installation orientation | any | 
| Storage temperature | -25 ... 70 °C | 
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 | 
| Degree of protection | IP65 (IP20) (in the installed state) | 
| Ambient temperature | |
| at UB = 24 V DC | -25 ... 55 °C | 
| Material | Fiber glass reinforced plastic | 
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| B10D | Mission time | |
|---|---|---|
| Emergency stop | 0.13x106 | 20 y | 
Miscellaneous
| Submodulbreite | 1 | 
| Additional feature | incl. lens set, ID no. 120344 | 
Modules MGB2-L2-BR-U-X0000-BX-138012
    Electrical connection values
| Connection cross section | |
| (rigid/flexible) | 0.25 ... 1.5 mm² ((AWG 23 ... AWG 16)) | 
| (rigid/flexible) with cable end sleeve according to DIN 46 228/1 | 0.25 ... 1.5 mm² | 
| (rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 | 0.25 ... 0.75 mm² | 
| Rated insulation voltage Ui | 75 V | 
| Rated impulse voltage Uimp | 1.5 kV | 
| Discrepancy time | |
| between FO1A and FO1B | max. 10 ms | 
| Utilization category | |
| DC-13 | 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) | 
| Risk time according to EN 60947-5-3 | max. 50 ms | 
| Risk time according to EN 60947-5-3, extension for each additional device | max. 10 ms | 
| Safety class | III | 
| Transponder coding | Unicode | 
| Degree of contamination (external, according to EN 60947-1) | 3 | 
| Monitoring outputs OD, OT/C, OL, OI | |
| Output type | Semiconductor outputs, p-switching, short circuit-proof | 
| Output voltage | UB-2 ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths) | 
| Output current | max. 50 mA | 
| Safety outputs FO1A, FO1B | |
| Output type | Semiconductor outputs, p-switching, short circuit-proof | 
| Output voltage | |
| UFO1A /UFO1B LOW | 0 ... 1 V DC | 
| UFO1A /UFO1B HIGH | UB-3,5 ... UB V DC (Value at a switching current of 150mA without taking into account the cable lengths) | 
| Output current | |
| per safety output FO1A / FO1B | 1 ... 150 mA | 
| Turn-on time | max. 80 ms | 
| Test pulse duration | max. 0.3 ms | 
| Test pulse interval | min. 100 ms | 
| Power supply UB | |
| Operating voltage DC | |
| UB | 24 V DC -15% ... +20% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) | 
| Current consumption | |
| IUB | max. 80 mA (at 20.4 V including safety inputs FI1A and FI1B, no load on outputs) | 
| Power supply IMP, IMM | |
| Solenoid operating voltage DC | |
| UIMP | 24 V DC -15% ... +20% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) | 
| Current consumption | |
| IIMP | max. 375 mA | 
| Test pulse duration | max. 5 ms | 
| Test pulse interval | min. 100 ms | 
Mechanical values and environment
| Ready delay | 5 s | 
| Switching frequency | 0.25 Hz | 
| Storage temperature | -30 ... 70 °C | 
| Mechanical life | |
| in case of use as door stop, and 1 Joule impact energy | 0.2 x 10⁶ | 
| Total | 1 x 10⁶ | 
| in case of use as door stop, and 2 Joule impact energy | 0.1 x 10⁶ | 
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 | 
| Degree of protection | IP65 (In the closed state when the connection cables, connecting cables and submodules are correctly mounted.) | 
| Ambient temperature | |
| at UB = 24 V DC | -30 ... 55 °C | 
| Material | |
| Housing | Fiber glass reinforced plastic; die-cast zinc, nickel plated | 
| Locking force FZh | 2000 N | 
| Guard locking principle | Open-circuit current principle | 
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| PL | Maximum SIL | PFHD | Category | Mission time | |
|---|---|---|---|---|---|
| Control of guard locking | PL e | 3 | 2.95x10-9 | 4 | 20 y | 
| Monitoring of the guard position | PL e | 3 | 2.95x10-9 | 4 | 20 y | 
| Monitoring of guard locking | PL e | 3 | 2.95x10-9 | 4 | 20 y | 
Miscellaneous
| Slotkonfiguration | 1 | 
Submodules MSM-C-K-BA-SBS-S0-160847
    Mechanical values and environment
| Connection type | Cable entries M20x1.5 | 
| Installation orientation | any | 
| Storage temperature | -25 ... 70 °C | 
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 | 
| Degree of protection | IP65 (IP20) (in the installed state) | 
| Ambient temperature | -25 ... 55 °C | 
| Material | Fiber glass reinforced plastic | 
Miscellaneous
| Slide-in label | |||||||
  | |||||||
| Additional feature | |||||||
| Incl. label holder, ID no. 156733 | |||||||
| incl. socket connector set, ID no. 136572 | |||||||
Connection accessories AC-MC-00-0-B-156718
    Electrical connection values
| Degree of contamination according to EN 60664-1 | 3 | 
Mechanical values and environment
| Storage temperature | -30 ... 70 °C | 
| Ambient temperature | -30 ... 55 °C | 
| Material | Fiber glass reinforced plastic | 
| Connection 1 | |
| Connection type | 2x M4 screws | 
| Degree of protection | IP65 (Only in the screwed tight state with the specified base units.) | 
Miscellaneous
| Color | black | 
| Additional feature | |
| incl. fixing screws | |
| incl. seal | 
Components

				100465
MGB-E-A-100465
Escape release MGB-E-A...
				MGB-E-A-100465
Escape release MGB-E-A...
- Escape release from the danger zone
 - Signal red door handle
 - Designed for door profiles up to 40 mm
 - Extended actuation axis for thicker doors (available optionally)
 

				164387
MGB2-L2-BR-U-XB2S0-DY-L-164387
Locking module MGB2-L2-BR... (2 pushbuttons, emergency stop, open-circuit current principle, door hinge on left)
				MGB2-L2-BR-U-XB2S0-DY-L-164387
Locking module MGB2-L2-BR... (2 pushbuttons, emergency stop, open-circuit current principle, door hinge on left)
- Guard locking with guard lock monitoring
 - Emergency stop according to ISO 13850
 - 2 illuminated pushbuttons
 - 3 adhesive labels
 - Cable entry M20 x 1.5 (order cable gland separately)
 - Adjustable door hinge; factory setting: left
 - Unicode
 

				156396
MGB2-H-BA1A1-L-156396
Handle module MGB2-H... (door handle, door hinge on left)
				MGB2-H-BA1A1-L-156396
Handle module MGB2-H... (door handle, door hinge on left)
- Intelligent bolt tongue
 - Fold-out lockout mechanism
 - Door handle
 - Adjustable door hinge; factory setting: left
 
Accessories
				
				Function expansion
				
				
				
				
					
							Lock for auxiliary release for safety switch CTP/CTA/TP/STP
					
					
					
					
		
		
			
			
					
					
					
				
		
		
			
			
					
					
					
				
		
		
			
			
					
					
					
				
		
		
			
			
					
					
					
				

				084177
AE-K-A1-DULK1-84177
				AE-K-A1-DULK1-84177
- Lock unique locking
 - Key removable in “unlocked” and “locked” positions
 

				086236
AE-K-A1-IULK1-86236
				AE-K-A1-IULK1-86236
- Identical locking
 - Key removable in “unlocked” and “locked” positions
 

				109212
AE-K-A1-IUK2-109212
				AE-K-A1-IUK2-109212
- Identical locking
 - Key can be removed only in “unlocked” position
 

				121917
AE-K-A1-ILK1-121917
				AE-K-A1-ILK1-121917
- Identical locking
 - Key removable in “locked” position
 
				
				Miscellaneous
				
				
				
				Mounting accessories
				
				
				
				
					
							Mounting plate for evaluation modules MGB2-L/I
					
					
					
					
		
		
			
			
					
					
					
				
		
		
			
			
					
					
					
				

				161315
AM-P-L-161315
				AM-P-L-161315
- For evaluation modules MGB2-L/I
 - Easy and quick mounting (only two screws required)
 - Quick module replacement
 - Steel, powder coated
 - Suitable for doors hinged on the right and left
 - Incl. screw set
 

				173091
AM-P-L-173091
				AM-P-L-173091
- For evaluation modules MGB2-L/I
 - Easy and quick mounting (only two screws required)
 - Quick module replacement
 - Steel, powder coated
 - Suitable for doors hinged on the right and left
 - Incl. screw set
 
					
							Mounting plate for handle module MGB2-H...
					
					
					
					
		
		
			
			
					
					
					
				
		
		
			
			
					
					
					
				

				156683
AM-P-H-156683
				AM-P-H-156683
- For handle module MGB2-H
 - Easy and quick mounting
 - Quick module replacement
 - Steel, powder coated
 - Suitable for doors hinged on the right and left
 - incl. screw set
 

				173089
AM-P-H-173089
				AM-P-H-173089
- For handle module MGB2-H
 - Easy and quick mounting
 - Quick module replacement
 - Steel, powder coated
 - Suitable for doors hinged on the right and left
 - incl. screw set
 
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
 - Any data sheets to supplement the operating instructions
 - The declaration of conformity
 
							Download Complete Package (ZIP, 22,0 MB)
						
Single Documents
				
				Data sheets
				
				
				
				
					
						Data sheet
					
					
					
					
					
						
						
					
						
						
					
						
						
					
						
						
Doc. no.
Version
Language
Size
Data sheet
Fiche technique
Ficha de datos
Datenblatt
Ficha de dados
数据表
データ シート
데이터 시트
Datový list
Fiche technique
Ficha de datos
Datenblatt
Ficha de dados
数据表
データ シート
데이터 시트
Datový list
Doc. no.
										2150276
Version
										02
Language
										Size
										0,2 MB
Data sheet
Fiche technique
Ficha de datos
Datenblatt
Ficha de dados
数据表
データ シート
데이터 시트
Datový list
Fiche technique
Ficha de datos
Datenblatt
Ficha de dados
数据表
データ シート
데이터 시트
Datový list
Doc. no.
										2150620
Version
										03
Language
										Size
										0,2 MB
Data sheet
Fiche technique
Ficha de datos
Datenblatt
Ficha de dados
数据表
データ シート
데이터 시트
Datový list
Fiche technique
Ficha de datos
Datenblatt
Ficha de dados
数据表
データ シート
데이터 시트
Datový list
Doc. no.
										2151082
Version
										02
Language
										Size
										0,2 MB
Data sheet
Fiche technique
Ficha de datos
Datenblatt
Ficha de dados
数据表
データ シート
데이터 시트
Datový list
Fiche technique
Ficha de datos
Datenblatt
Ficha de dados
数据表
データ シート
데이터 시트
Datový list
Doc. no.
										2151453
Version
										01
Language
										Size
										0,1 MB
				
				Declarations of conformity
				
				
				
				
					
						EU-Konformitätserklärung
					
					
					
					
					
						
						
Doc. no.
Version
Language
Size
EU-Konformitätserklärung
Doc. no.
										EDC2500504
Version
										Language
										Size
										0,2 MB
				
				Instructions
				
				
				
				
					
						Operating Instructions Safety Systems MGB2-L1…-BR.-… / MGB2-L2…-BR.-… and MGB2-L1…-BP.-… / MGB2-L2…-BP.-…
					
					
					
					
					
						
						
					
						
						
					
						
						
					
						
						
Doc. no.
Version
Language
Size
Operating Instructions Safety Systems MGB2-L1…-BR.-… / MGB2-L2…-BR.-… and MGB2-L1…-BP.-… / MGB2-L2…-BP.-…
Doc. no.
										2500233
Version
										02/23
Language
										Size
										7,5 MB
Mode d’emploi Systèmes de sécurité MGB2-L1…-BR.-… / MGB2-L2…-BR.-… et MGB2-L1…-BP.-… / MGB2-L2…-BP.-…
Doc. no.
										2500233
Version
										02/23
Language
										Size
										7,5 MB
Betriebsanleitung Sicherheitssysteme MGB2-L1…-BR.-… / MGB2-L2…-BR.-… und MGB2-L1…-BP.-… / MGB2-L2…-BP.-…
Doc. no.
										2500233
Version
										02/23
Language
										Size
										7,5 MB
Návod k použití Bezpečnostní systémy MGB2-L1…-BR.-… / MGB2-L2…-BR.-… a MGB2-L1…-BP.-… / MGB2-L2…-BP.-…
Doc. no.
										2500233
Version
										02/23
Language
										Size
										7,8 MB
Other Documents
				
				Approvals and certificates
				
				
				
				
					
						FCC
					
					
					
					
					
						
						
Doc. no.
Version
Language
Size
FCC
Doc. no.
										Version
										Language
										Size
										0,2 MB
					
						WEEE
					
					
					
					
					
						
						
Doc. no.
Version
Language
Size
WEEE
Doc. no.
										ECO20001806
Version
										Language
										Size
										0,1 MB
Ordering data
| Ordernumber | 164385 | 
| Item designation | MGB2-L2HE-BR-U-S0-DY-L-164385 | 
| Gross weight | 3,34kg | 
| Customs tariff number | 85371098 | 
| ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking | 
				