CET4-AP-CRA-AH-50X-SA-122415 (Order no. 122415)

Safety switch with guard locking CET-AP-..., RFID, plug connector(s) M12

  • Open-circuit current principle
  • Unicode
  • Monitoring output guard locking OUT
  • Monitoring output door position OUT D
  • Plug connector M12, 8-pin
CET4-AP-CRA-AH-50X-SA-122415 (Order no. 122415)

Description

Approach direction

Horizontal

Can be adjusted in 90° steps

Guard locking principle

Open-circuit current (power on to lock): On a guard with guard locking based on the open-circuit current principle, the guard is locked until the power supply to the guard locking solenoid is interrupted. Unlocking is by spring force. The term electrical guard locking is also used.

Unicode evaluation

Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in.

Only the last actuator taught-in is detected.

Safety characteristics

Thanks to two redundant safety outputs (semiconductor outputs) with internal monitoring, the device is suitable for:

  • Category 4 /PL e according to EN 13849-1
  • SIL 3 according to EN IEC 62061 Table 4

The OSSD outputs used check their function for short circuits and short circuits with test pulses.

LED indicator

LED STATE

Status LED

DIA LED

Diagnostics LED

LED 1 rd

illuminates when the solenoid is energized

LED 2 gn

illuminates when door is closed

Terminal assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1UCMSolenoid operating voltage, 24 V DCWH
2UBElectronics operating voltage, 24 V DCBN
3OASafety output, channel AGN
4OBSafety output, channel BYE
5OUTMonitoring outputGY
6OUT DDoor position monitoring outputPK
70 V UBElectronics operating voltage, 0 V DCBU
80V UCMSolenoid operating voltage, 0 V DCRD

Accessories required

Actuator is not included.

The safety switch can only be actuated in conjunction with the actuators provided for this purpose.

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
Connector assignment
Connector assignment
CET: Transponder-coded safety switch with guard locking in use
CET3-AP: Mounting emergency release safety swith CET3-AP
CET3-AP: Mounting and Setup CET3-AP (closed-circuit current principle)
CET3-AP: Mounting auxiliary release with key CET3-AP

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/8

Workspace

Repeat accuracy R
according to EN 60947-5-2 10 %

Electrical connection values

Fuse
external (solenoid operating voltage UCM) 0.5 ... 8 A
external (operating voltage UB) 0.25 ... 8 A
Power consumption
Solenoid 11 W
Connecting cable 30V DC, 2A (for UL requirement UL category code (CYJV/CYJV7))
Operating voltage DC
UB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV (The device tolerates voltage interruptions of up to 5 ms)
LED 24 V DC -15% V DC ... +10% V DC
EMC protection requirements Acc. to EN IEC 60947-5-3
Utilization category
DC-13 24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Solenoid operating voltage DC
UCM 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV
Solenoid duty cycle 100 %
Risk time according to EN 60947-5-3 max. 400 ms
Switching load
according to UL 24V DC, Class 2 (For alternatives, see operating instructions)
Safety class III
Current consumption
ICM 450 mA
IB 80 mA
Test pulse duration max. 0.3 ms (Applies to a load with C<= 30nF and R<= 20kOhm)
Degree of contamination (external, according to EN 60947-1) 3
Monitoring output OUT D
Output type p-switching, short circuit-proof
Output voltage
OUT D 0.8xUB ... UB V DC
Switching current
OUT D 1 ... 50 mA
Switching delay from state change max. 700 ms
Monitoring output OUT
Output type p-switching, short circuit-proof
Output voltage
OUT 0.8xUB ... UB V DC
Switching current
OUT 1 ... 50 mA
Switching delay from state change max. 400 ms
Safety outputs OA / OB
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Output voltage
LOW U(OA,OB) 0 ... 1 V DC
HIGH U(OA,OB) UB-1.5V ... UB V DC
Discrepancy time
both safety outputs max. 10 ms
Turn-on time 400 ms
Off-state current Ir max. 0.25 mA
Switching current
per safety output OA / OB 1 ... 200 mA

Mechanical values and environment

Anfahrgeschwindigkeit max. 20 m/min
Connection type 1 plug connector M12, 8-pin
Ready delay 1 s
Installation orientation any
Switching frequency max. 0.5 Hz
Degree of freedom X ±5 mm
Degree of freedom Y ±5 mm
Degree of freedom Z ±4 mm
Storage temperature -25 ... 70 °C
Mechanical life 2 x 10⁶
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP67 (In the inserted and screwed tight state)
Ambient temperature
at UB = 24 V DC -20 ... 55 °C
Material
Safety switch housing Die-cast aluminum
Ramp Stainless steel
Locking force Fmax 6500 N
Locking force FZh 5000 N (FZH = FMAX/1.3)
Guard locking principle Open-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of guard lockingPL e-3.1x10-9420 y


Miscellaneous

Notices for UL approval Operation only with UL Class 2 power supply or equivalent measures; see operating instructions

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 9,8 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 122415
Item designation CET4-AP-CRA-AH-50X-SA-122415
Gross weight 1,273kg
Customs tariff number 85365019000
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking