TX2C-A024RC18 (Order no. 082940)

Safety switch TX, plug connector M23 (RC18)

  • Plug connector M23 (RC18)
  • Contacts for the door position
  • Auxiliary release
  • LED indicator
  • Open-circuit current principle
TX2C-A024RC18 (Order no. 082940)

Description

Approach direction

Horizontal and vertical

Can be adjusted in 90° steps

LED indicator

The switch has two freely assignable LED indicators (red and green).

Guard locking principle

Open-circuit current (power on to lock): On a guard with guard locking based on the open-circuit current principle, the guard is locked until the power supply to the guard locking solenoid is interrupted. Unlocking is by spring force. The term electrical guard locking is also used.

Switching element

ETX C

Slow-action switching contact

Contacts for guard locking: 2 positively driven contacts + 1 NO contact

Contacts for door monitoring: 1 NO contact

Auxiliary release

The auxiliary release on the front makes it possible to access the machine if there is a malfunction, e.g. a power failure. Unlocking is performed using a tool or a key. The auxiliary release must be protected against misuse (sealing, lacquer).

Accessories required

Actuator is not included.

Switching function
Switching function
Dimension drawing
Dimension drawing
Wiring diagram ETX C
Wiring diagram ETX C
Electromechanical safety switches in use

Functional drawings

Functional drawings

Dimensional drawings

Dimensional drawings
1Auxiliary release
2LED indicator
3Locking screw
sInsertion depth

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20DNV-GL_TAA0000172 Rev. 1DGUV_TX_ET 23014_ET 23015CCC2024010305643586_SafetySwitch T_STc_UL_us_E155795_2/4

Operating and display elements

LED display Operating voltage corresponds to the solenoid voltage (2 LEDs; green, red)

Electrical connection values

Fuse max. 4 A gG (>70 °C =>2 A gG)
Power consumption 8 W
Rated insulation voltage Ui 50 V
Rated impulse voltage Uimp 1.5 kV
Utilization category
DC-13 4 A 24 V (>70 °C =>2 A)
AC-15 4 A 50 V (>70 °C =>2 A)
Solenoid operating voltage
AC/DC 24 V -15% ... +10%
Solenoid duty cycle 100 %
Switching voltage
min. at 10 mA 12 V
Switching current
min. at 24 V 1 mA
thermal rated current Ith 4 A (>70 °C =>2 A)

Mechanical values and environment

Approach speed max. 20 m/min
Approach direction A
Connection type
1 x Plug connector RC18 (18-pin + PE)
Number of door position NO contacts 1
Number of guard lock monitoring NO contacts 1
Number of guard lock monitoring positively driven contacts 2
Extraction force 35 N
Actuation frequency max. 1200 1/h
Actuating force 35 N
Installation orientation any
Insertion depth 32 mm
Mechanical life 1 x 10⁶
Retention force 20 N
Switching principle Slow-action switching contact
Degree of protection IP65
Ambient temperature -20 ... 80 °C
Material
Contact Silver alloy, gold flashed
Housing Die-cast alloy cathodically dipped
Locking force Fmax 1700 N
Locking force FZh 1300 N
Guard locking principle Open-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

B10DMission time
Monitoring of guard locking5x10620 y
Important! Values valid at DC-13 100 mA/24V


In combination with actuator ACTUATOR-X-GQ

Overtravel 1 mm

In combination with actuator ACTUATOR-X-GNQ

Overtravel 8 mm

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 3,3 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 082940
Item designation TX2C-A024RC18
Gross weight 0,909kg
Customs tariff number 85365019000
ECLASS 27-27-26-03 Safety switch with guard control