CES-I-BP-M-C07-SB-160076 (Order no. 160076)
Safety switch CES-I-BP-.-C07-..., RFID, plug connector(s) M12
- Multicode
- Door position monitoring output
- Plug connector M12, 5-pin

Description
Typical operating distance
(only in combination with actuator CES-A-BTN-C07)
For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the actuating range of the side lobes is not entered.
Attention:
The actuating range may vary depending on the actuator, substrate material and installation situation. You can find additional actuating ranges in the operating instructions.
Multicode evaluation
It is checked whether the actuator is of a type that can be detected by the system (multicode evaluation). The system possesses a low coding level. Every suitable actuator is detected by the switch.
Safety characteristics
Due to two redundantly designed safety outputs (semiconductor outputs) with internal monitoring, the device is suitable for:
- Category 4 /PL e according to EN 13849-1
- SIL 3 according to EN IEC 62061
The OSSD outputs used check their function for short circuits using test pulses.
LED indicator
STATE | Status LED |
DIA | Diagnostics LED |
Terminal assignment
Plug connector aligned C07
The following applies to the device installation position shown: cable outlet C (left), cable outlet A (right).
Scope of delivery
- Caps for the mounting holes
Accessories required
Actuator is not included.
Dimensional drawings

| 1 | LEDs |
| 2 | Active face |
| 3 | With the installation orientation shown: cable outlet on left or right |
Connection examples

Technical data
Approvals




Workspace
| Repeat accuracy R | |
| according to EN 60947-5-2 | 10 % |
Electrical connection values
| Fuse | |
| external (operating voltage) | 0.25 ... 8 A |
| rated conditional short-circuit current | 100 A |
| Rated insulation voltage Ui | 75 V |
| Rated impulse voltage Uimp | 1.5 kV |
| Operating voltage DC | |
| UB | 24 V DC -15% ... +15% regulated, residual ripple<5%, PELV |
| Turn-on time | |
| Safety outputs | max. 100 ms |
| EMC protection requirements | Acc. to EN IEC 60947-5-3 |
| Risk time according to EN 60947-5-3 | max. 125 ms |
| Safety class | III |
| Current consumption | 40 mA |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| Monitoring output OD/C | |
| Output type | p-switching, short circuit-proof |
| Output voltage | UB-1.5 ... UB V DC |
| Switching current | 1 ... 50 mA |
| Safety outputs FO1A/FO1B | |
| Output type | Semiconductor outputs, p-switching, short circuit-proof |
| Output voltage | |
| HIGH U(FO1A) / U(FO1B) | UB-1.5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.) |
| LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
| Discrepancy time | max. 10 ms |
| Utilization category | |
| DC-13 | 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
| Off-state current Ir | max. 0.25 mA |
| Switching current | 1 ... 150 mA |
| Test pulse duration | 0.3 ms (Applies to a load with C<= 30nF and R<= 20kOhm) |
| Test pulse interval | ca 100 ms |
Mechanical values and environment
| Dimensions | 40 x 26.5 x 18 |
| Connection type | M12 plug connector, 5-pin |
| Tightening torque | max. 0.8 Nm |
| Ready delay | 5 s |
| Operating altitude | max. 4 000 m |
| Installation orientation | any |
| Switching frequency | max. 1 Hz |
| Storage temperature | -25 ... 70 °C |
| Mounting distance | |
| between switches | min. 50 mm |
| Mounting type | Surface mounting on metal |
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
| Degree of protection | IP65/IP67/IP69/IP69K |
| Ambient temperature | |
| at UB = 24 V DC | -25 ... 55 °C (+65 °C at IL = max. 10 mA per safety output) |
| Material | |
| Housing | Plastic, PBT-PC-GF30 |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| Mission time | |
| according to EN ISO 13849-1 | |
| SIL CL | |
| according to EN 62061:2005/A2:2015 |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| PL | Maximum SIL | PFHD | Category | Mission time | |
|---|---|---|---|---|---|
| Monitoring of the guard position | PL e | 3 | 6x10-10 | 4 | 20 y |
Miscellaneous
| Notices for UL approval | Operation only with UL Class 2 power supply or equivalent measures |
| Additional feature | Caps included |
In combination with actuator A-C11-01-175934
| Switch-on distance | |
| Installation position B | 5 mm on steel |
| Installation position A | 6,5 mm on steel |
| Secured switch-off distance sar | |
| Installation position A + B | max. 15 mm |
| Secured switching distance sao | |
| Installation position A | 4 mm |
| Installation position B | 2 mm (only up to 0°C) |
In combination with actuator CES-A-BDN-06-158210
| Switch-on distance | |
| Installation position A | 16 mm |
| Installation position B | 11 mm |
| Installation position D | 7 mm |
| Installation position C | 8 mm |
| Secured switch-off distance sar | |
| in x direction/installation position A | max. 24 mm |
| in x direction/installation position C | max. 21 mm |
| Secured switching distance sao | |
| in x direction/installation position C | min. 6 mm |
| in x direction/installation position A | min. 13 mm |
In combination with actuator CES-A-BTN-C07-156230
| Switch-on distance | |
| Installation position C + D | 7 mm |
| Installation position A + B | 13 mm |
| Secured switch-off distance sar | |
| in x direction/installation position A + B | max. 20 mm |
| in x direction/installation position C + D | max. 17 mm |
| Secured switching distance sao | |
| in x direction/installation position B | min. 9 mm |
| in x direction/installation position C | min. 3 mm |
| in x direction/installation position A | min. 10 mm |
| in x direction/installation position D | min. 2 mm |
In combination with actuator CES-A-BDN-06-158210, CES-A-BTN-C07-156230
| Switching hysteresis | 1 ... 2 mm |
Accessories

C-M12F05-05X034PU10,0-M12M05-119947
- M12 female plug to M12 plug connector, 5-pin
- Straight female plug and plug connector
- PUR cable
- Cable length 10 m

C-M12F05-05X034PV10,0-M12M05-100181
- M12 female plug to M12 plug connector, 5-pin
- Straight female plug and plug connector
- PVC cable
- Cable length 10 m

C-M12F05-05X034PU20,0-M12M05-119971
- M12 female plug to M12 plug connector, 5-pin
- Straight female plug and plug connector
- PUR cable
- Cable length 20 m

C-M12F05-05X034PV20,0-M12M05-100182
- M12 female plug to M12 plug connector, 5-pin
- Straight female plug and plug connector
- PVC cable
- Cable length 20 m

C-M12F05-05X034PU05,0-M12M05-119932
- M12 female plug to M12 plug connector, 5-pin
- Straight female plug and plug connector
- PUR cable
- Cable length 5 m

C-M12F05-05X034PV05,0-M12M05-100180
- M12 female plug to M12 plug connector, 5-pin
- Straight female plug and plug connector
- PVC cable
- Cable length 5 m

C-M12F05-05X025PU10,0-M12M05-115565
- M12 female plug, 5-pin (angled) to M12 plug connector (straight)
- plug connectors at both ends
- PUR cable
- Cable length 10 m
- with cable exit A (right)

C-M12F05-05X025PU10,0-M12M05-115566
- M12 female plug, 5-pin (angled) to M12 plug connector (straight)
- plug connectors at both ends
- PUR cable
- Cable length 10 m
- with cable exit C (left)
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Other Documents
Ordering data
| Ordernumber | 160076 |
| Item designation | CES-I-BP-M-C07-SB-160076 |
| Gross weight | 0,05kg |
| Customs tariff number | 85365019000 |
| ECLASS | 27-27-24-03 Safety-related transponder switch |