EUCHNER – More than safety.
EUCHNER – More than safety.

Safety switch CTM-BP

Benefits for you

  • Communicating safety switch with guard locking and safe guard lock monitoring
  • Industry 4.0 ready
  • Integrated short circuit monitoring by pulsing
  • Two safe semiconductor outputs
  • Bistable guard locking principle
  • Safety category 4 and PL e according to EN ISO 13849-1.

Industry 4.0 ready

The switch can communicate in combination with an EUCHNER IO-Link Gateway, and sends process and device data to higher-level control systems. Comprehensive diagnostic messages enable rapid and targeted troubleshooting.

Function

Thanks to the transponder technology, even a single CTM achieves category 4/PL e according to EN ISO 13849-1, without additional fault exclusion, and meets all the requirements of EN ISO 14119. It is ideal for applications requiring a high performance level in a confined space.
Safety switch CTM-BP

Versatile use

The CTM reliably secures small safety doors and flaps on machines and systems. Thanks to the integrated guard locking and guard lock monitoring, it can be used both for process protection and the protection of personnel.
The compact design permits space-saving mounting on the guard. The very robust plastic housing and the high degree of protection IP65/IP67/IP69/IP69K make the CTM the all-rounder for almost every industrial use.
With its smooth surfaces, rounded edges, and materials resistant to cleaning agents, the CTM is particularly suitable for use in the food and packaging industries.

Mounting and principle of operation

The CTM consists of two components, a safety switch and a separate actuator. The safety switch is mounted on the fixed part of the guard, the actuator on the movable part. The compact dimensions (120 mm x 36 mm x 25 mm) permit simple integration into any machine design.
Door pivoting radii as small as 150 mm are possible thanks to the innovative ball actuator. The integral adhesive force (25/50 N) effectively prevents doors from being opened when they are not locked.
When the guard is closed, the actuator moves into the opening of the safety switch. The safety outputs are switched on if the integrated transponder chip in the actuator is detected and the guard locking activated. Thanks to the integrated prevention of inadvertent locking position (faulty closure protection), unintentional activation of the safety outputs is prevented if the actuator is not completely inserted into the guard locking opening.

Diagnostic information

The safety switches of series CTM can forward comprehensive diagnostic information to the control system. The devices supply process-relevant parameters in real time. They even provide information on preventive maintenance. The sensors measure relevant parameters in the surroundings to indicate problems before a machine failure can occur. In combination with the IO-Link Gateways GWY-CB and ESM-CB, this information is polled from every switch and provided to the control system via IO-Link.

Products (6)

No results found

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com