IO-Link Gateway for BP/BR switches
- IO-Link device for reading process and device data of BP/BR safety switches and transferring them to a higher-level control system
- Control of guard locking of BP/BR switches, depending on the switch used
- Compact version measuring only 12.5 mm in width
- Rail mounting
- LED status indicators

Description
Industry 4.0 ready
Process data are cyclically sent to the control system via IO-Link. These data include all status signals, such as the door or guard locking position, and the indication of whether a switch is in the limit range of the actuating range.
The process data are available to the control system after approx. 200 ms and can be used for the automation process.
Plug and Play series connection
- Connection for safety switches with BR technology without addressing the individual switches
- The wiring and configuration work is minimized.
Device data and events
The higher-level control system can poll more than 30 different items of information from the connected switches. Comprehensive data transmission via IO-Link enables targeted preventive maintenance, for example.
Simple implementation of innovative applications
Device data from the actuators used can be employed to detect individual rotary table positions or different containers, for example.


Dimension drawings

Connection examples

Technical data
Controls and indicators
LED indicator | 1x operating voltage display PWR green, 1x status display DIA red, 1x IO-Link green |
Electrical connection ratings
Connection cross-section | 0.2 ... 1.5 mm² |
Rated insulation voltage Ui | 30 V |
Duty cycle | 100 % |
Overvoltage category according to IEC EN 60664-1 | 2 |
Power dissipation | max. 0.1 W |
Degree of contamination (external, according to EN 60947-1) | 2 |
IO-Link | |
Current consumption | |
Supply: L+/L- | 14 mA |
Process data update | 5 ms |
Power supply | |
Supply: L+/L | 24 24 V DC -20% / +25% |
Reverse polarity protection | Serial reverse polarity protection |
Supply A1/A2 | |
Current consumption | 60 mA |
Operating voltage DC | |
Us | 24 V DC -20% ... +25% (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent insulation measures.) |
Reverse polarity protection | Serial reverse polarity protection |
Mechanical values and environment
Stripping length | 8 mm |
Dimensions | 12.5 x 108.6 x 114.5 |
Connection | plug-in spring terminals |
Degree of protection | |
IP20 | |
IP54 (Installation location, min.) | |
Material | |
Housing | PBT, gray |
Installation orientation | vertical or horizontal |
Atmospheric humidity | max. 75 % rH |
Mounting type | Mounting rail 35 mm according to DIN EN 60715 TH35 |
Ambient temperature | |
(operation) | -25 ... +60 °C |
permissible shock and vibration load | 10 Hz...150 Hz, 2 g |
IO-Link | |
Connection type | 3-conductor |
Number of inputs | |
Switching and communication line: C | 1 |
Number of masters | 1 |
Connection | spring terminals |
Miscellaneous
IO-Link | |
Product version number | Version 1.1 |
Interface, bus
IO-Link | |
Data rate | 230 kbit/s |
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents






Other Documents





Ordering data
Ordernumber | 165049 |
Item designation | GWY-CB-1-BR-IO-165049 |
Gross weight | 0,117kg |
Customs tariff number | 85364110 |