Interlocking module and bus module MGB-L0...-PN with 2 control elements, 7/8" and M12 plugs
- Interlocking (without guard locking)
- Emergency stop according to ISO 13850, illuminated
- 2 illuminated pushbuttons
- including adhesive labels
- Connection via 7/8" and M12 plugs
- Pre-assembled on mounting plates
- Integrated Profinet RT switch
- Unicode

Description
Profinet connection
7/8" plugs according to ANSI/B93.55M-1981 and M12 plugs (d-coded) according to IEC 61076-2-101
Profinet RT switch
Point-to-point topology network structure due to integrated RT switch.
Illuminated emergency stop
Emergency stop with illumination that can be controlled as required.

Dimension drawings

Technical data
Approvals



Work area
Assured release distance sar | |
Door position | max. 65 mm |
Controls and indicators
Assignment diagram | |
B1 | |
L0 |
Item | Extras | Color | Designation1 | Number | LED | Note slide-in label | Version | Slide-in label inscription | Switching element |
---|---|---|---|---|---|---|---|---|---|
90 | Illuminated pushbutton | 1NO | |||||||
93 | Emergency stop illuminated | 2 PD | |||||||
95 | Illuminated pushbutton | 1NO |
Electrical connection ratings
Connecting cable | |
Ethernet | PROFINET I/O cable, at least cat. 5e |
Current consumption | max. 500 mA |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 0.5 kV |
EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
maximum feed-in current in the connection block | |
X1, X2 | max. 4000 mA |
Safety class | III |
Transponder coding | Unicode |
Degree of contamination (external, according to EN 60947-1) | 3 |
Power supply X1 | |
Fusing | |
external | min. 1 A slow blow |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple <5%, PELV)) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system) |
Power supply X2 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Mechanical values and environment
Connection | |
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e | M12, D-coded, screened (X3 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.)) |
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e | M12, D-coded, screened (X4 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.)) |
7/8" Power (X2 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.)) | |
7/8" Power (X1 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.)) | |
Degree of protection | IP54 |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Mechanical life | |
1 x 10⁶ | |
in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ |
Installation orientation | Door hinge DIN left |
Switching frequency | 0.25 Hz |
Reaction time | |
Door position | max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Bolt position | max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Emergency stop / machine stop | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Shock and vibration resistance | according to EN 60947-5-3 |
Ambient temperature | |
at UB = 24V DC | -20 ... +55 °C |
Reliability values according to EN ISO 13849-1
Mission time | 20 y |
Emergency stop | |
B10D | |
Emergency stop | 0.13 x 10⁶ |
Emergency-stop evaluation | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10-8 |
Monitoring of the guard position | |
Diagnostic Coverage (DC) | 99 % |
Category | 4 |
Performance Level | PL e |
PFHD | 4.07 x 10-8 (Fixed failure rate without consideration of faults in wearing parts.) |
Safety Integrity Level | SIL 3 (EN 62061:2005) |
Miscellaneous
Additional feature | incl. lens set, ID no. 120344 | Slide-in label | |||||
| |||||||
Product version number | V3.30.10 |
Interface, bus
Bus data protocol | Profinet (IEC 61158 type 10) |
Safety data protocol | Profisafe (IEC 61784-3-3) |
Data interface | |
Ethernet |
Accessories
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents



Other Documents

Homologation
Homologación
EAC
Homologação
Omologazione
认证
認可
승인
Сертификат
Atest
Engedély
Разрешително
Godkendelse
Heakskiit
Hyväksyntä
Έγκριση
Odobrenje
Atļauja
Patvirtinimas
Goedkeuring
Godkjenning
Dopuszczenie
Godkännande
Dovoljenje
Povolenie
Onay
Дозвіл


Ordering data
Ordernumber | 124128 |
Item designation | MGB-L0B-PNA-L-124128 |
Gross weight | 3,496kg |
European Article Number (EAN) | 4047048006430 |
Customs tariff number | 85365019 |