EUCHNER – More than safety.
EUCHNER – More than safety.

ZSA072969C1983 (Order no. 072969)

ZSA, 3-stage with cable

  • Housing G1
  • 3-stage function
  • Straight connecting cable, 15 m
  • LED
ZSA072969C1983 (Order no. 072969)

Description

Switching element

2220

2 NO/NC

Cable

The high-quality connecting cables (individual screening of the safety contacts) are available in a straight version.

LEDs

The LEDs are used for visual feedback direct at the enabling switch.

3-stage function

Enabling function is active only in the second stage (center position, actuating point). If the pushbutton is released or pushed further (panic function), the enabling is removed (dependent on the wiring, see function sequence).

Dimension drawing
Dimension drawing
Wiring diagram 2220 with 2 LEDs
Wiring diagram 2220 with 2 LEDs
Travel diagram
Travel diagram

Dimensional drawings

Dimensional drawings
1LED GN (2x)

Connection examples

Connection examples

Shift travel diagrams

Shift travel diagrams
closed, enabling
closed
open

Technical data

Approvals

CCC2020980305002418_CQC2009010305380679_2024EAC_RU C-DE.MO05.B.00972/20c_UL_us_E206093_4/2

Operating and display elements

ItemExtrasColorDesignation1NumberLEDNote slide-in labelSwitching elementSlide-in labelVersion
gn2LED

Electrical connection values

Connecting cable 8x0.34 mm² (4x0.34 mm² screened + 4x0.34 mm² unscreened)
rated conditional short-circuit current 100 A
Rated insulation voltage Ui 32 V
Rated impulse withstand voltage Uimp 2.5 kV
Utilization category
DC-13 2 A 24 V
AC-15 2 A 24 V
Short circuit protection according to IEC 60269-1 2A gG (In case of operating voltages other than 24 V, the short circuit protection must be dimensioned accordingly and checked.)
Switching voltage
min. at 10 mA 12 V
Switching current
min. at 24 V 1 mA
Switching characteristics 3-stage enabling switch
Degree of contamination (external, according to EN 60947-1) 3
Display/control element
Utilization category
DC-13 Additional elements 100 mA 24 V
AC-15 Additional elements 400 mA 24 V
Short circuit protection according to IEC 60269-1
Additional elements at 24V 0.1A gG (In case of operating voltages other than DC 24 V, the short circuit protection must be dimensioned accordingly and checked.)

Mechanical values and environment

Connection type flying lead
Number of NO contacts 2
Number of positively driven contacts 2
Cable length
straight 15 m
Mechanical life
Position 1-2-1 0.1 x 10⁶
Position 1-2-3-1 0.1 x 10⁶
Switching principle Slow-action contact element
Degree of protection IP65
Ambient temperature -5 ... +50 °C
Material Plastic

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Enabling switch
B10D 0.5 x 10⁶

Miscellaneous

in compliance with 60947-5-8

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 2,0 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 072969
Item designation ZSA072969C1983
Gross weight 1,5kg
Customs tariff number 85365019000
ECLASS 27-37-12-38 Agreement switch

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com