MSM-1-R-DA-SISISI-H1-165628 (Order no. 165628)
Choose content
Submodule MSM-1-R... (3 x M12 plug connectors for OSSD safety switches)
- Function expansion for modules MGB2 and MCM
- Connection type: R
- 3 x M12 plug connectors for connecting OSSD safety switches
- Status LED per M12 plug connector

Description
Dimensional drawings

1 | Coding alignment |
2 | Red built-in socket |
LED1 | LED indicator |
LED2 | LED indicator |
LED3 | LED indicator |
Pos 1 | M12 plug connector for connecting an OSSD safety switch |
Pos 2 | M12 plug connector for connecting an OSSD safety switch |
Pos 3 | M12 plug connector for connecting an OSSD safety switch |
Z | marks orientation of item 1 |
Dimensional drawings

Technical data
Operating and display elements
Item | Color | Extras | Slide-in label | Version | Switching element | Note slide-in label | Number | Designation1 | LED |
---|---|---|---|---|---|---|---|---|---|
1 | Connection M12x1 for OSSD device | ||||||||
2 | Connection M12x1 for OSSD device | ||||||||
3 | Connection M12x1 for OSSD device |
Electrical connection values
Current consumption | max. 50 mA |
Controls and indicators | |
Breaking capacity | max. 0.25 W |
Switching voltage | 24 V |
Switching current | 5 ... 10 mA |
Mechanical values and environment
Installation orientation | any |
Response time | See operating instructions for bus module MBM-... or interlocking/locking module MGB2-I.-BR-... / MGB2-L.-BR-... |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP65 (IP20) (in the installed state) |
Ambient temperature | |
at UB = 24 V DC | -25 ... 55 °C |
Material | Fiber glass reinforced plastic, die-cast zinc, nickel plated |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Evaluating safety signals | PL e | - | 9.06x10-10 | 4 | 20 y |
Only applies to externally connected safety functions such as enabling switches, safety switches, etc. |
Miscellaneous
Submodulbreite | 1 |
Software ID (SW ID) | 165628 |
Accessories
CES-AP
Safety switch CES-AP-CR2-..., RFID, connection cable, connecting cable PUR with plug connector(s) M12, for connection to decentralized peripheral systems

109168
CES-AP-CR2-CH-SB-109168
CES-AP-CR2-CH-SB-109168
- Multicode
- Connecting cable PUR, 0.2 m, plug connector M12, 5-pin; pin 5 not used
- for connection to decentralized peripheral systems
- Door hinge right

111748
CES-AP-CR2-AH-SB-111748
CES-AP-CR2-AH-SB-111748
- Unicode
- Connecting cable PUR, 0.2 m, plug connector M12, 5-pin; pin 5 not used
- for connection to decentralized peripheral systems
- Door hinge right
Safety switch CES-I-AP-.-C04-..., RFID, plug connector(s) M12, for connection to decentralized peripheral systems

115150
CES-I-AP-U-C04-USI-115150
CES-I-AP-U-C04-USI-115150
- Unicode
- Connecting cable PUR, 0.1 m, plug connector M12, 5-pin; pin 5 not used
- for connection to decentralized peripheral systems

117323
CES-I-AP-M-C04-USI-117323
CES-I-AP-M-C04-USI-117323
- Multicode
- Connecting cable PUR, 0.1 m, plug connector M12, 5-pin; pin 5 not used
- for connection to decentralized peripheral systems

160832
CES-I-AP-M-C04-USI-160832
CES-I-AP-M-C04-USI-160832
- Multicode
- Connecting cable PUR, 1.5 m, plug connector M12, 5-pin; pin 5 not used
- for connection to decentralized peripheral systems

162592
CES-I-AP-M-C04-USI-162592
CES-I-AP-M-C04-USI-162592
- Multicode
- Connecting cable PUR, 2 m, plug connector M12, 5-pin; pin 5 not used
- for connection to decentralized peripheral systems
CES-FD
Field evaluation unit CES-FD-AP-…

115534
CES-FD-AP-M-01-USI-115534
CES-FD-AP-M-01-USI-115534
- Connection of a CES/CKS read head
- Evaluation of signals in the field
- Connection to the ET200s and ET200pro
- Familiar EUCHNER AP interface
- Multicode

119865
CES-FD-AP-U-01-USI-119865
CES-FD-AP-U-01-USI-119865
- Connection of a CES/CKS read head
- Evaluation of signals in the field
- Connection to the ET200s and ET200pro
- Familiar EUCHNER AP interface
- Unicode
CES-I-BP
Safety switch CES-I-BP-.-C07-..., RFID, plug connector(s) M12

160076
CES-I-BP-M-C07-SB-160076
CES-I-BP-M-C07-SB-160076
- Multicode
- Door position monitoring output/communication OD/C
- Diagnostic information via BR/IO-Link gateway
- Plug connector M12, 5-pin

160080
CES-I-BP-U-C07-SB-160080
CES-I-BP-U-C07-SB-160080
- Unicode
- Door position monitoring output/communication OD/C
- Diagnostic information via BR/IO-Link gateway
- Plug connector M12, 5-pin
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Download Complete Package (ZIP, 2,9 MB)
Declarations of conformity
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size

UKCA-Konformitätserklärung
Doc. no.
EDC20001508
Version
Language
Size
0,2 MB
Instructions
Operating Instructions Submodule MSM-1-R-.A-…
Doc. no.
Version
Language
Size

Operating Instructions Submodule MSM-1-R-.A-…
Doc. no.
2539735
Version
12/22
Language
Size
1,1 MB

Mode d’emploi Sous-module MSM-1-R-.A-…
Doc. no.
2539735
Version
12/22
Language
Size
1,1 MB

Manual de instrucciones Submódulo MSM-1-R-.A-…
Doc. no.
2539735
Version
12/22
Language
Size
1,1 MB

Betriebsanleitung Submodul MSM-1-R-.A-…
Doc. no.
2539735
Version
12/22
Language
Size
1,1 MB
CAD data
Ordering data
Ordernumber | 165628 |
Item designation | MSM-1-R-DA-SISISI-H1-165628 |
Gross weight | 0,125kg |
Customs tariff number | 85371098 |
ECLASS | 27-24-26-05 Field bus, decentralized peripheral - function-/technology module |