Evaluation module and bus module MGB-L2...-PN... (guard locking by solenoid force) with 5 control elements, 7/8" plug and M12 plug
- Guard locking with guard lock monitoring
- Emergency stop according to ISO 13850, illuminated
- 4 illuminated pushbuttons
- including adhesive labels
- Connection via 7/8" and M12 plugs
- Including terminal plug for Stacklight (M12, 5-pin)
- Pre-assembled on mounting plates
- Integrated Profinet RT switch
- Unicode

Description
Profinet connection
7/8" plugs according to ANSI/B93.55M-1981 and M12 plugs (d-coded) according to IEC 61076-2-101
Profinet RT switch
Point-to-point topology network structure due to integrated RT switch.
Flexible use as interlocking or guard locking
By means of the corresponding evaluation of the safe device data by the control system, use can be as either interlocking or guard locking (with or without monitoring).

Dimension drawing

Technical data
Approvals





Mechanical values and environment
Shock and vibration resistance | In acc. with EN 60947-5-3 |
Housing material | |
Housing | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 3,1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP54 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN right |
Reaction time | |
Bolt position | max.550 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Guard locking | max.550 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Emergency stop / machine stop | max.250 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Door position | max.550 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Switching frequency | 0,25 Hz |
Connection | Plug connector M12 (X6) |
Acc. to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e | M12 D-coded, screened (X4 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.)) |
7/8" Power (X1 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.)) | |
7/8" Power (X2 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.)) | |
Acc. to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e | M12 D-coded, screened (X3 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.)) |
Guard locking principle | Open-circuit current principle |
Locking force FZh | 2000 N |
Electrical connection ratings
Current consumption | max.500 mA |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 0,5 kV |
Maximum feed-in current in the connection block | |
X1, X2 | max.4000 mA |
EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | |
Ethernet | Profinet I/O cable, at least cat. 5e |
Safety class | III |
Transponder coding | Unicode |
Power supply X1 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV)) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system) |
Fusing | |
external | min.1 A Slow blow |
Power supply X2 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... 10% (For looping through for connected devices) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Work area
Assured release distance Sar | |
Door position | max.65 mm |
Interface, bus
Bus data protocol | Profinet (IEC 61158 type 10) |
Safety data protocol | Profisafe (IEC 61784-3-3) |
Data interface | |
Ethernet |
Controls and indicators
Assignment diagram | B1 |
Assignment diagram | L1 |
Position 1 | |
Version | Emergency stop illuminated |
Slide-in label | |
Special features | |
Color | |
Switching element | 2 pos. driven NC |
Position 90 | |
Version | Illuminated push buttons |
Slide-in label | |
Special features | |
Color | Red |
Switching element | 1NO |
Position 92 | |
Version | Illuminated push buttons |
Slide-in label | |
Special features | |
Color | Green |
Switching element | 1NO |
Position 93 | |
Version | Illuminated push buttons |
Slide-in label | |
Special features | |
Color | Yellow |
Switching element | 1NO |
Position 95 | |
Version | Button |
Slide-in label | |
Special features | |
Color | Green |
Switching element | 1NO |
Other
Product version number | V3.30.10 |
Slide-in label | Incl. 4 slide-in labels, silver color, without marking |
Reliability values according to EN ISO 13849-1
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.07 x 10-8 (Fixed failure rate without consideration of faults in wearing parts.) |
Diagnostic Coverage (DC) | 99 |
Control of the guard locking | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.91 x 10-8 |
Emergency stop | |
B10D | |
Emergency stop | 0,13 x 106 |
Emergency-stop evaluation | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10-8 |
Safety Integrity Level | SIL 3 (EN 62061:2005) |
Mission time | 20 |
Accessories
Downloads
Instructions
Operating Instructions Safety Systems MGB-L..B-PN.-... (PROFINET) with Data Structure Type B from V3.30.0
Doc. no.
Version
Language
Size

Operating Instructions Safety Systems MGB-L..B-PN.-... (PROFINET) with Data Structure Type B from V3.30.0
Doc. no.
2115174
Version
09-02/21
Language
Size
3,9 MB

Betriebsanleitung Sicherheitssysteme MGB-L..B-PN.-... (PROFINET) mit Datenstruktur Typ B ab V3.30.0
Doc. no.
2115174
Version
09-02/21
Language
Size
3,9 MB
Consent