CES-AP-C01-AH-SB-111145 (Order no. 111145)

Safety switch CES-AP-C01-..., RFID, plug connector(s) M12, for connection to decentralized peripheral systems

  • Unicode
  • Plug connector(s) M12, 5-pin, pin 5 not assigned
  • for connection to decentralized peripheral systems
CES-AP-C01-AH-SB-111145 (Order no. 111145)

Description

Direct connection to decentralized peripheral systems

The connection via M12 plug connector(s) is optimized for direct connection to IP67 IO modules, such as ET200pro and ET200eco from SIEMENS, MVK from MURR and EP1957 from BECKHOFF.

Approach direction and installation position

1 active face, adjustable in 5 directions

Typical actuating ranges

With actuators CES-A-BBA and CES-A-BCA

<p>With actuators CES-A-BBA and CES-A-BCA</p>

For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm must be maintained so that the actuating range of the side lobes is not entered.

With actuator CES-A-BPA

<p>With actuator CES-A-BPA</p>

For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the actuating range of the side lobes is not entered.

Attention:

The actuating range may vary depending on the actuator, substrate material and installation situation. Further actuating ranges can be found in the operating instructions.

Unicode evaluation

Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in.

Only the last actuator taught-in is detected.

Safety characteristics

Thanks to two redundant safety outputs (semiconductor outputs) with internal monitoring, the device is suitable for:

  • Category 4 /PL e according to EN 13849-1
  • SIL 3 according to EN IEC 62061 Table 4

The OSSD outputs used check their function for short circuits and short circuits with test pulses.

LED indicator

STATE

Status LED

DIA

Diagnostics LED

Terminal assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1UBPower supply, DC 24 VBN
2OASafety output, channel 1WH
30 VGround, DC 0 VBU
4OBSafety output, channel 2BK
5-n.c.GY

Plug connector(s) adjusted C01

Plug connector(s) adjustable in 6 orientations.

Accessories required

Wiring diagram
Wiring diagram

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E346349_1/1

Workspace

Repeat accuracy R 10 %

Electrical connection values

Fuse
external (operating voltage) 0.25 ... 8 A
Rated insulation voltage Ui 75 V (Tested by the employers’ liability insurance association up to 75 V.)
Rated impulse voltage Uimp 1.5 kV
Operating voltage DC
UB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
Turn-on time
Safety outputs max. 400 ms
EMC protection requirements Acc. to EN IEC 60947-5-3
Risk time according to EN 60947-5-3 max. 260 ms
Safety class III
Current consumption
no load on outputs max. 50 mA
Degree of contamination (external, according to EN 60947-1) 3
Safety outputs OA / OB
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage
HIGH U(OA,OB) UB-1.5 ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.)
LOW U(OA,OB) 0 ... 1 V DC
rated conditional short-circuit current 100 A
Discrepancy time max. 10 ms
Utilization category
DC-13 24V 400mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
Off-state current Ir max. 0.25 mA
Switching current
per safety output 1 ... 400 mA
Test pulse duration max. 0.4 ms

Mechanical values and environment

Connection type M12 plug connector, 5-pin; pin 5 not used
Tightening torque
Fixing screws max. 1 Nm
Ready delay 0.5 s
Installation orientation any
Switching frequency max. 1 Hz
Mounting distance min. 40 mm
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP67
Ambient temperature -20 ... 55 °C
Material
Housing Plastic, PBT

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of the guard positionPL e-2.1x10-9420 y


Miscellaneous

Notices for UL approval Operation only with UL Class 2 power supply or equivalent measures

In combination with actuator CES-A-BBA-071840

Switch-on distance 18 mm
Secured switch-off distance sar max. 45 mm (for surface mounting)
Secured switching distance sao min. 15 mm (for surface mounting)
Switching hysteresis 1 ... 3 mm (for surface mounting)

In combination with actuator CES-A-BPA-098775

Switch-on distance 22 mm (on surface mounting on aluminum. In a non-metallic environment, the typical operating distances increase to 30 mm)
Secured switch-off distance sar max. 58 mm
Secured switching distance sao min. 18 mm
Switching hysteresis 1 ... 2 mm

In combination with actuator CES-A-BRN-100251

Switch-on distance 27 mm
Secured switch-off distance sar max. 75 mm
Secured switching distance sao min. 20 mm (The values apply to surface mounting of the actuator on steel.)
Switching hysteresis 3 mm (The values apply to surface mounting of the actuator on steel.)

In combination with actuator CES-A-BDA-18-156935

Switch-on distance 19 mm (for surface mounting)
Secured switch-off distance sar max. 45 mm (for surface mounting)
Secured switching distance sao min. 10 mm (for surface mounting)
Switching hysteresis 1 ... 3 mm (for surface mounting)

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 10,2 MB)

Single Documents

Doc. no.
Version
Language
Size
Doc. no. 2112663
Operating Instructions Non-Contact Safety Switch CES-AP-C01-… (Unicode/Multicode)
Doc. no.
2112663
Version
09-07/23
Language
Size
1,4 MB
Doc. no. 2112663
Mode d’emploi Interrupteur de sécurité sans contact CES-AP-C01-… (unicode / multicode)
Doc. no.
2112663
Version
09-07/23
Language
Size
1,4 MB
Doc. no. 2112663
Manual de instrucciones Interruptor de seguridad sin contacto CES-AP-C01-… (Unicode/Multicode)
Doc. no.
2112663
Version
09-07/23
Language
Size
1,4 MB
Doc. no. 2112663
Betriebsanleitung Berührungsloser Sicherheitsschalter CES-AP-C01-… (Uni-/Multicode)
Doc. no.
2112663
Version
09-07/23
Language
Size
1,4 MB
Doc. no. 2112663
Manual de instruções Chaves de segurança sem contato CES-AP-C01-… (Unicode/Multicode)
Doc. no.
2112663
Version
09-07/23
Language
Size
1,4 MB
Doc. no. 2112663
Istruzioni di impiego Finecorsa di sicurezza senza contatto CES-AP-C01-… (Unicode/Multicode)
Doc. no.
2112663
Version
09-07/23
Language
Size
1,4 MB
Doc. no. 2112663
使用说明书 非接触式安全开关 CES-AP-C01-… (特殊/通用编码)
Doc. no.
2112663
Version
09-07/23
Language
Size
1,9 MB
Doc. no. 2112663
Инструкция по эксплуатации Бесконтактный предохранительный выключатель CES-AP-C01-… (Uni-/Multicode)
Doc. no.
2112663
Version
09-07/23
Language
Size
1,9 MB
Doc. no. 2112663
Návod k použití Bezkontaktní bezpečnostní spínač CES-AP-C01-… (Unicode/Multicode)
Doc. no.
2112663
Version
09-07/23
Language
Size
1,9 MB
Doc. no. 2112663
Instrukcja obsługi Bezstykowy wyłącznik bezpieczeństwa CES-AP-C01-… (Uni-/Multicode)
Doc. no.
2112663
Version
09-07/23
Language
Size
1,9 MB
Doc. no. 2112663
Návod na prevádzku Bezdotykový bezpečnostný spínač CES-AP-C01-… (Uni-/Multicode)
Doc. no.
2112663
Version
09-07/23
Language
Size
1,9 MB

Other Documents

Ordering data

Ordernumber 111145
Item designation CES-AP-C01-AH-SB-111145
Gross weight 0,147kg
Global Trade Item Number (GTIN) 4047048006737
Customs tariff number 85365019000
ECLASS 27-27-24-03 Safety-related transponder switch