Transponder-coded safety switch CTP-AP, M23, 2 pushbuttons (extended)
- Safety switch with guard locking and integrated evaluation electronics
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4 / PL e according to EN ISO 13849-1
- 2 pushbuttons (illuminated)
- With plug connector M23
- Unicode
- Door monitoring output
- Approach directions A, B and C (delivery state)

Description
Unicode evaluation
Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.
Guard locking type
CTP‑L2 | Guard locking actuated by power-ON and released by spring force (open-circuit current principle). |
Lens set
The color of the pushbuttons can be selected using the color cover set included (5 colors). Item no.: 120344 (see Accessories)
Connector assignment
Plug connector (view of connection side) | Pin | Designation | Function | Connecting cable conductor coloring |
---|---|---|---|---|
1 | IMP | Operating voltage of guard locking solenoid, 24 V DC | VT | |
2 | - | n.c. | RD | |
3 | - | n.c. | GY | |
4 | FO1A | Safety output, channel 1 | RD/BU | |
5 | FO1B | Safety output, channel 2 | GN | |
6 | UB | Operating voltage of AP electronics, controls and indicators 24 V DC | BU | |
7 | RST | Reset input | GY/PK | |
8 | OD | Door monitoring output | GN/WH | |
9 | OI | Diagnostic output | YE/WH | |
10 | OL | Guard lock monitoring output | GY/WH | |
11 | - | n.c. | BK | |
12 | FE | Functional earth (must be connected to meet the EMC requirements) | GN/YE | |
13 | IMM | Operating voltage of guard locking solenoid, 0 V | PK | |
14 | - | n.c. | BN/GY | |
15 | S2 | Pushbutton 2 (illuminated) | BN/YE | |
16 | H2 | LED 2 | BN/GN | |
17 | S3 | Pushbutton 3 (illuminated) | WH | |
18 | H3 | LED 3 | YE | |
19 | 0 V UB | Operating voltage of AP electronics, controls and indicators 0 V | BN |
Dimension drawings

1 | LEDs |
2 | Auxiliary release |
3 | Pushbutton (illuminated) |
4 | Pushbutton (illuminated) |
Connection examples

Technical data
Approvals





Work area
Repeat accuracy R | |
according to EN 60947-5-2 | 10 % |
Controls and indicators
Item | Extras | Color | Designation1 | Number | LED | Note slide-in label | Version | Slide-in label inscription | Switching element |
---|---|---|---|---|---|---|---|---|---|
2 | Illuminated pushbutton | 1NO | |||||||
3 | Illuminated pushbutton | 1NO |
Electrical connection ratings
Current consumption | |
IUB | 40 mA |
IIMP | 400 mA |
Fusing | |
external (solenoid operating voltage IMP) | 0.5 ... 8 A |
external (operating voltage UB) | 0.25 ... 8 A |
Rated insulation voltage Ui | 50 V |
Rated impulse withstand voltage Uimp | 0.5 kV |
Operating voltage DC | |
UUB | 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple < 5%, PELV |
EMC protection requirements | according to EN IEC 60947-5-3 |
Power consumption | 6 W |
Utilization category | |
DC-13 | 24V 150mA (Caution: Outputs must be protected with a free-wheeling diode in case of inductive loads) |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple < 5%, PELV |
Solenoid duty cycle | 100 % |
Switching load | |
according to UL | 24V DC, Class 2 (alternatively, see operating instructions) |
Safety class | |
EN IEC 61140 | III |
Test pulses | max. 0.3 ms (Applies to a load with C <= 30 nF and R <= 20 kohm) |
Test pulse interval | min. 100 ms |
Degree of contamination (external, according to EN 60947-1) | 3 |
Controls and indicators | |
Current consumption | |
LED | 10 mA |
Operating voltage | UB V |
Operating current | 1 ... 50 mA |
Power supply | |
LED | 24 V |
Monitoring output OD, OI, OL | |
Output type | p-switching, short circuit-proof |
Output voltage | 0.8xUB ... UB V DC |
Switching current | 1 ... 50 mA |
Safety outputs FO1A / FO1B | |
Output type | 2 semiconductor outputs, p-switching, short circuit-proof |
Discrepancy time | |
both safety outputs | max. 10 ms according to EN IEC 60947-5-3 |
Output voltage | |
HIGH U(FO1A) / U(FO1B) | UB-1.5 ... UB V DC |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Turn-on time | max. 400 ms |
Switching current | |
per safety output FO1A / FO1B | 1 ... 150 mA |
Off-state current Ir | max. 0.25 mA |
Mechanical values and environment
Approach speed | max. 20 m/min |
Connection | 1 plug connector M23, 19-pin, RC18 |
Degree of protection | IP65 (screwed tight plug connector/mating component) |
Extraction force | 20 N |
Ready delay | max. 1 s |
Material | |
Switch head cover | Die-cast zinc |
Safety switch housing | reinforced thermoplastic |
Actuating force | 10 N |
Mechanical life | 1 x 10⁶ |
Installation orientation | any |
Switching frequency | max. 0.5 Hz |
Retention force | 20 N |
Overtravel | 5 mm |
Shock and vibration resistance | according to EN 60947-5-3 |
Ambient temperature | |
at UB = 24V DC | -20 ... +55 °C |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N (Fzh = Fmax/1.3, depending on the actuator used) |
Guard locking principle | Open-circuit current principle |
Reliability values according to EN ISO 13849-1
Mission time | 20 y |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10 -9 |
Miscellaneous
Additional feature | incl. lens set, ID no. 120344 |
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures; see operating instructions |
Accessories

A-C-H-RU-LS-122676
- Hinged actuator for bottom-hinged doors
- Two safety screws included

A-C-H-RR-LS-122672
- Hinged actuator for doors hinged on the right
- Two safety screws included

A-C-H-RO-LS-122675
- Hinged actuator for top-hinged doors
- Two safety screws included

A-C-H-RL-LS-122671
- Hinged actuator for doors hinged on the left
- Two safety screws included

C-M23F19-19XDIFPU01,5-MA-092907
- M23 plug connector, 18-pin + PE
- Angled plug connector
- Cable exit A (right)
- PUR cable
- Cable length 1.5 m
- With flying lead
- Cores color-coded

C-M23F19-19XDIFPU01,5-MA-092906
- M23 plug connector, 18-pin + PE
- Angled plug connector
- Cable exit C (left)
- PUR cable
- Cable length 1.5 m
- With flying lead
- Cores color-coded

C-M23F19-19XDIFPU10,0-MA-092902
- M23 plug connector, 18-pin + PE
- Angled plug connector
- Cable exit A (right)
- PUR cable
- Cable length 10 m
- With flying lead
- Cores color-coded

C-M23F19-19XDIFPU10,0-MA-092901
- M23 plug connector, 18-pin + PE
- Angled plug connector
- Cable exit C (left)
- PUR cable
- Cable length 10 m
- With flying lead
- Cores color-coded

C-M23F19-19XDIFPU15,0-MA-085196
- M23 plug connector, 18-pin + PE
- Angled plug connector
- Cable exit A (right)
- PUR cable
- Cable length 15 m
- With flying lead
- Cores color-coded

C-M23F19-19XDIFPU15,0-MA-077020
- M23 plug connector, 18-pin + PE
- Angled plug connector
- Cable exit C (left)
- PUR cable
- Cable length 15 m
- With flying lead
- Cores color-coded

C-M23F19-19XDIFPU20,0-MA-092910
- M23 plug connector, 18-pin + PE
- Angled plug connector
- Cable exit C (left)
- PUR cable
- Cable length 20 m
- With flying lead
- Cores color-coded

C-M23F19-19XDIFPU20,0-MA-092911
- M23 plug connector, 18-pin + PE
- Angled plug connector
- Cable exit A (right)
- PUR cable
- Cable length 20 m
- With flying lead
- Cores color-coded

C-M23F19-19XDIFPU25,0-MA-092912
- M23 plug connector, 18-pin + PE
- Angled plug connector
- Cable exit C (left)
- PUR cable
- Cable length 25 m
- With flying lead
- Cores color-coded

C-M23F19-19XDIFPU25,0-MA-092913
- M23 plug connector, 18-pin + PE
- Angled plug connector
- Cable exit A (right)
- PUR cable
- Cable length 25 m
- With flying lead
- Cores color-coded

C-M23F19-19XDIFPU03,0-MA-092909
- M23 plug connector, 18-pin + PE
- Angled plug connector
- Cable exit A (right)
- PUR cable
- Cable length 3 m
- With flying lead
- Cores color-coded

C-M23F19-19XDIFPU03,0-MA-092908
- M23 plug connector, 18-pin + PE
- Angled plug connector
- Cable exit C (left)
- PUR cable
- Cable length 3 m
- With flying lead
- Cores color-coded

C-M23F19-19XDIFPU06,0-MA-077018
- M23 plug connector, 18-pin + PE
- Angled plug connector
- Cable exit C (left)
- PUR cable
- Cable length 6 m
- With flying lead
- Cores color-coded

C-M23F19-19XDIFPU06,0-MA-085194
- M23 plug connector, 18-pin + PE
- Angled plug connector
- Cable exit A (right)
- PUR cable
- Cable length 6 m
- With flying lead
- Cores color-coded

C-M23F19-19XDIFPU08,0-MA-077019
- RC18 plug connector, 18-pin + PE
- Angled plug connector
- Cable exit C (left)
- PUR cable
- Cable length 8 m
- With flying lead
- Cores color-coded

C-M23F19-19XDIFPU08,0-MA-085195
- M23 plug connector, 18-pin + PE
- Angled plug connector
- Cable exit A (right)
- PUR cable
- Cable length 8 m
- With flying lead
- Cores color-coded

RIEGEL CTP-AC-123653
- Steel bolt
- For doors hinged on the right and left
- Can be locked in open position with padlocks
- Actuator included

RIEGEL CTP-AC-C2308-137354
- Steel bolt
- For doors hinged on the right and left
- Can be locked in open position with padlocks
- Actuator included
- Bolt without door stop, suitable for swing doors

AM-C-SW4-V3-161344
- Plastic inserts for hexagon socket screws a/f 4
- Efficient protection against tampering for safety switch mounting
- The packaging includes inserts for 18 screws

AM-C-SW5-V3-161348
- Plastic inserts for hexagon socket screws a/f 5
- Efficient protection against tampering for safety switch mounting
- The packaging includes inserts for 18 screws
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents








Other Documents

Homologation
Homologación
EAC
Homologação
Omologazione
认证
認可
승인
Сертификат
Atest
Engedély
Разрешително
Godkendelse
Heakskiit
Hyväksyntä
Έγκριση
Odobrenje
Atļauja
Patvirtinimas
Goedkeuring
Godkjenning
Dopuszczenie
Godkännande
Dovoljenje
Povolenie
Onay
Дозвіл






Ordering data
Ordernumber | 158402 |
Item designation | CTP-L2-AP-U-HA-AZE-SH-158402 |