CTP-L1-AP-U-HA-AES-SA-157112 (Order no. 157112)

Transponder-coded safety switch CTP-AP, M12, stainless steel, escape release

  • Safety switch with guard locking and integrated evaluation electronics
  • Version with stainless-steel components
  • ECOLAB certificate
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4/PL e according to EN ISO 13849-1
  • With plug connector M12
  • Unicode
  • Door monitoring output
  • With escape release
  • Approach directions A, B and C (delivery state)
CTP-L1-AP-U-HA-AES-SA-157112 (Order no. 157112)

Description

Medium-resistant stainless-steel version

Robust, tough and largely media resistant. Critical components such as plugs, cover screws and guide bushes, etc., consist of high-quality inox steel.

Approach direction

Figure

Figure

Horizontal

Can be adjusted in 180° steps

Unicode evaluation

Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.

Guard locking type

CTP‑L1Guard locking actuated by spring force applied and power-ON released (closed-circuit current principle)

Escape release

This is used for manual release of guard locking from the danger zone without tools.

Connector assignment

Plug connector (view of connection side)

Pin

Designation

Function

Conductor coloring of connecting cable

1

IMP

Operating voltage of guard locking solenoid, 24 V DC

WH

2

UB

Operating voltage of AP electronics, 24 V DC

BN

3

FO1A

Safety output, channel 1

GN

4

FO1B

Safety output, channel 2

YE

5

OI

Diagnostic output

GY

6

OD

Door monitoring output

PK

7

0 V UB

Operating voltage of AP electronics, 0 V

BU

8

IMM

Operating voltage of guard locking solenoid, 0 V

RD

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
CTP: Transponder coded safety switch CTP

Dimension drawing

Dimension drawing
1Auxiliary release
2Locking screw
3LEDs

Wiring diagram

Wiring diagram

Technical data

Approvals

Zulassung EACZertifikat ECOLABZulassung c_UL_us LISTED Class 2 or LV/C

Mechanical values and environment

Shock and vibration resistance In acc. with EN 60947-5-3
Housing material
Metal material Stainless steel
Safety switch housing Fiber glass reinforced thermoplastic
Actuating button POM-C
Weight
Net 0,53 kg
Ambient temperature
At UB = 24V DC -20 ... +55 °C
Degree of protection IP67/IP69/IP69K (Screwed tight plug connector/mating component)
Mechanical life 1 x 106
Installation orientation Any
Ready delay max.1 s
Switching frequency max.0,5 Hz
Connection 1 plug connector M12, 8-pin
Approach speed max.20 m/min
Guard locking principle Closed-circuit current principle
Locking force Fmax 3900 N
Locking force FZh 3000 N (Fzh = Fmax/1.3 Depending on the actuator used)
Retention force 20 N
Extraction force 20 N
Actuating force 10 N
Overtravel 5 mm

Electrical connection ratings

Test-pulse interval min.100 ms
Test pulses max.0,3 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
Operating voltage DC
UUB 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Current consumption
IUB 40 mA
IIMP 400 mA
Utilization category acc. to EN 60947-5-2
DC-13 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Solenoid operating voltage DC
UIMP 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Fusing
External (operating voltage UB) 0,25 ... 8 A
External (solenoid operating voltage IMP) 0,5 ... 8 A
Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 0,5 kV
Connection rating 6 W
EMC protection requirements In acc. with EN IEC 60947-5-3
Solenoid duty cycle 100 %
Degree of contamination (external, according to EN 60947-1) 3
Safety class
EN IEC 61140 III
Switching load
According to UL 24V DC, class 2 (Alternatively see operating instructions)
Safety outputs FO1A / FO1B
Type of output 2 semiconductor outputs, p-switching, short circuit-proof
Switching current
Per safety output FO1A / FO1B 1 ... 150 mA
Output voltage
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
HIGH U(FO1A) / U(FO1B) UB-1,5 ... UB V DC
Off-state current Ir max.0,25 mA
Turn-on time max.400 ms
Discrepancy time
Both safety outputs max.10 ms In acc. with EN IEC 60947-5-3
Monitoring output OD
Type of output p-switching, short circuit-proof
Switching current 1 ... 50 mA
Output voltage 0,8xUB ... UB V DC
Monitoring output OI
Type of output p-switching, short circuit-proof
Switching current 1 ... 50 mA
Output voltage 0,8xUB ... UB V DC

Work area

Repeat accuracy R
According to EN 60947-5-2 10 %

Other

Additional feature Escape release actuated by pushing
For the approval acc. to UL the following applies Operation only with UL class 2 power supply, or equivalent measures see operating instructions

Reliability values according to EN ISO 13849-1

Performance Level PL e
Category 4
PFHD 4.1 x 10 -9
Mission time 20 y

Accessories