EUCHNER – More than safety.
EUCHNER – More than safety.

CET4-AR-CDA-CH-50X-SG-114712 (Order no. 114712)

Non-contact safety switch CET-AR-..., M12, with double ramp

  • Safety switch with guard locking and integrated evaluation electronics
  • Locking force up to 6500 N
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4 / PL e according to EN ISO 13849-1
  • With 2 plug connectors M12
  • Multicode
  • Door monitoring output
  • Indication of the door position by LED
  • With double ramp
  • Approach directions A and C (delivery state)
CET4-AR-CDA-CH-50X-SG-114712 (Order no. 114712)

Description

Approach direction

Horizontal

Can be adjusted in 90° steps

Safety switch

The device may be operated only in conjunction with the actuator CET-A-....

Important: The actuator must be ordered separately.

Multicode evaluation unit

Every suitable actuator is detected by the switch.

Solenoid operating voltage

  • DC 24 V +10%, -15%

Guard locking type

CET4

Open-circuit current principle, guard locking by solenoid force. Activation of the guard locking by applying voltage to the guard locking solenoid. The door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). The output OUT D also remains set when guard locking is active.

LED function display

State LED

Status LED

DIA LED

Diagnostics LED

LED 1 rd

freely configurable

LED 2 gn

illuminates when door is closed

Additional connections

OUT

Monitoring output (semiconductor)

OUT D

Door monitoring output

RST

Reset input

Category according to EN ISO 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4 / PL e according to EN ISO 13849-1
  • The stated safety characteristics apply to any installation orientations of the safety switch.

Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
CET: Transponder-coded safety switch with guard locking in use

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/8

Workspace

Repeat accuracy R
according to EN 60947-5-2 10 %

Electrical connection values

Fuse
external (operating voltage UB) 0.25 ... 8 A
external (solenoid operating voltage UCM) 0.5 ... 8 A
Power consumption
Solenoid 11 W
Connecting cable 30V DC, 2A (for UL requirement UL category code (CYJV/CYJV7))
Operating voltage DC
UB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
LED 24 V DC -15% V DC ... +10% V DC
EMC protection requirements Acc. to EN IEC 60947-5-3
Utilization category
DC-13 24 V 200 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Solenoid operating voltage DC
UCM 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV
Solenoid duty cycle 100 %
Risk time according to EN 60947-5-3 max. 400 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 5 ms
Switching load
according to UL 24V DC, Class 2 (For alternatives, see operating instructions)
Safety class
EN IEC 61140 III
Current consumption
IB 80 mA
ICM 450 mA
Test pulse duration max. 1 ms
Degree of contamination (external, according to EN 60947-1) 3
Monitoring output OUT D
Output type p-switching, short circuit-proof
Output voltage
OUT D 0.8xUB ... UB V DC
Switching current
OUT D 1 ... 50 mA
Switching delay from state change max. 700 ms
Monitoring output OUT
Output type p-switching, short circuit-proof
Output voltage
OUT 0.8xUB ... UB V DC
Switching current
OUT 1 ... 50 mA
Switching delay from state change max. 400 ms
Safety outputs OA / OB
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Output voltage
LOW U(OA,OB) 0 ... 1 V DC
HIGH U(OA,OB) UB-1.5V ... UB V DC
Discrepancy time
both safety outputs max. 10 ms
Turn-on time 400 ms
Off-state current Ir max. 0.25 mA
Risk time according to EN 60947-5-3
Single device
Switching current
per safety output OA / OB 1 ... 200 mA

Mechanical values and environment

Approach speed max. 20 m/min
Connection type 2 plug connectors M12, 5- and 8-pin
Ready delay 10 s
Installation orientation any (preferably head downward)
Switching frequency max. 0.5 Hz
Degree of freedom X ±5 mm
Degree of freedom Y ±5 mm
Degree of freedom Z ±4 mm
Mechanical life 2 x 10⁶
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP67 (screwed tight plug connector/mating component)
Ambient temperature
at UB = 24 V DC -20 ... +55 °C
Material
Ramp Stainless steel
Safety switch housing Die-cast aluminum
Locking force Fmax 6500 N
Locking force FZh 5000 N (FZH = FMAX/1.3)
Guard locking principle Open-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y
Monitoring of guard locking and the guard position
Category
Any installation orientation 4
Performance Level PL e
PFHD
Any installation orientation 3.1 x 10-9

Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures; see operating instructions

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 25,1 MB)

Single Documents

Doc. no.
Version
Language
Size
Doc. no. 2110788
Operating Instructions Transponder-Coded Safety Switch with Guard Locking CET.-AR-… (Unicode/Multicode)
Doc. no.
2110788
Version
11/22
Language
Size
3,8 MB
Doc. no. 2110788
Mode d’emploi Interrupteur de sécurité à codage par transpondeur avec interverrouillage CET.-AR-… (unicode / multicode)
Doc. no.
2110788
Version
11/22
Language
Size
3,9 MB
Doc. no. 2110788
Manual de instrucciones Interruptor de seguridad con codificación por transponder con bloqueo CET.-AR-… (Unicode/Multicode)
Doc. no.
2110788
Version
11/22
Language
Size
3,8 MB
Doc. no. 2110788
Betriebsanleitung Transpondercodierter Sicherheitsschalter CET.-AR-…
Doc. no.
2110788
Version
11/22
Language
Size
3,8 MB
Doc. no. 2110788
Istruzioni di impiego Finecorsa di sicurezza con codifica a transponder con meccanismo di ritenuta CET.-AR-… (Unicode/Multicode)
Doc. no.
2110788
Version
11/22
Language
Size
3,8 MB
Doc. no. 2110788
使用说明书 应答机编码安全开关 配有门锁功能 CET.-AR-… (特殊/通用编码)
Doc. no.
2110788
Version
11/22
Language
Size
4,2 MB
Doc. no. 2110788
操作説明書 トランスポンダー コーデッド安全スイッチ ガードロック付き CET.-AR-… (ユニコード/マルチコード)
Doc. no.
2110788
Version
11/22
Language
Size
4,2 MB
Doc. no. 2110788
Инструкция по эксплуатации Транспондерный предохранительный выключатель с защитной блокировкой CET.-AR-… (Uni-/Multicode)
Doc. no.
2110788
Version
11/22
Language
Size
4,2 MB
Doc. no. 2110788
Návod k použití Bezpečnostní spínač s kódovaným transpondérem a jištěním ochranného krytu CET.-AR-… (Unicode/Multicode)
Doc. no.
2110788
Version
11/22
Language
Size
4,2 MB
Doc. no. 2110788
Driftsvejledning Transponderkodet sikkerhedsafbryder med tilholder CET.-AR-… (Uni-/Multicode)
Doc. no.
2110788
Version
11/22
Language
Size
4,0 MB
Doc. no. 2110788
Instrukcja obsługi Wyłącznik bezpieczeństwa kodowany transponderowo z blokadą CET.-AR-… (Uni-/Multicode)
Doc. no.
2110788
Version
11/22
Language
Size
4,2 MB
Doc. no. 2110788
Návod na prevádzku Bezpečnostný spínač kódovaný transpondérom s istením CET.-AR-… (Uni-/Multicode)
Doc. no.
2110788
Version
11/22
Language
Size
4,2 MB
Doc. no. 2110788
İşletim kılavuzu Kapalı tutma mekanizmalı aktarıcı kodlu emniyet şalteri CET.-AR-… (Uni-/Multicode)
Doc. no.
2110788
Version
11/22
Language
Size
4,2 MB
Doc. no. 2110788
Instrucțiuni de utilizare Întrerupător de siguranță codat cu transponder cu blocare de protecție CET.-AR-… (Uni-/Multicode)
Doc. no.
2110788
Version
11/22
Language
Size
4,2 MB

Other Documents

Ordering data

Ordernumber 114712
Item designation CET4-AR-CDA-CH-50X-SG-114712
Gross weight 1,23kg
Customs tariff number 85365019000
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com