EUCHNER – More than safety.
EUCHNER – More than safety.

CEM-I2-AR-M-C40-SH-113739 (Order no. 113739)

Transponder-coded safety switch CEM-AR-C40

  • Safety switches with guard locking for process protection and integrated evaluation electronics
  • Solenoid with locking force 600 N
  • Adhesive-force adjustment in 3 levels
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1 for door position monitoring
  • With plug connector M23
  • Multicode
  • Door monitoring output
CEM-I2-AR-M-C40-SH-113739 (Order no. 113739)

Description

Multicode evaluation

Every suitable actuator is detected by the switch.

Guard locking type

CEM‑I2

Guard locking actuated by energy ON and released by energy OFF.

Connector assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1IMPControl voltage, guard locking solenoid, 24 V DCVT
2FI1AEnable input for channel 1RD
3FI1BEnable input for channel 2GY
4FO1ASafety output, channel 1RD/BU
5FO1BSafety output, channel 2GN
6UBOperating voltage 24 V DCBU
7RSTReset inputGY/PK
8OTDoor monitoring outputGN/WH
9OIDiagnostic outputYE/WH
10OLGuard lock monitoring outputGY/WH
11-n.c.BK
12FEFunctional earth (must be connected to meet the EMC requirements)GN/YE
13-n.c.PK
14-n.c.BN/GY
15-n.c.BN/YE
16-n.c.BN/GN
17-n.c.WH
18-n.c.YE
190 V UBOperating voltage, 0 VBN
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
CEM-AR-C40: Adhesive-force adjustment in 3 levels
CEM-AR-C40: Mounting and function lockout bar
Mounting and set up CEM-AR-C40
Transponder-coded safety Switch CEM-C40

Dimensional drawings

Dimensional drawings
1Active solenoid face
2Active read head face

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/11

Workspace

Secured switch-off distance sar 18 mm
Center offset
Solenoid -5 ... +5 mm (in all directions)

Electrical connection values

Fuse
external (operating voltage UB) 1 A
rated conditional short-circuit current 100 A
Rated insulation voltage Ui 30 V
Rated impulse withstand voltage Uimp 0.5 kV
Operating voltage
DC 24 V -15% ... +15% (PELV)
Discrepancy time max. 10 ms
Turn-on time 700 ... 2500 ms (Guard locking active)
EMC protection requirements Acc. to EN 60947-5-3
Risk time according to EN 60947-5-3 max. 260 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 5 ms
Safety class III
Current consumption
I UB, guard locking active 350 mA (Monitoring outputs not loaded)
I UB, guard locking inactive 80 mA (Monitoring outputs not loaded)
I IMP, control input min. 20 mA
Degree of contamination (external, according to EN 60947-1) 3
OT, OI, OL
Output type Semiconductor output, p-switching, short circuit-proof
Output voltage 0.8 x UB ... UB V DC
Switching current
per monitoring output max. 50 mA
FO1A/FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
HIGH U(FO1A) / U(FO1B) UB - 1.5 ... UB V DC
Utilization category
DC-13 DC-13 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Off-state current Ir max. 0.25 mA
Electrical switching frequency 0.5 Hz
Switching current
per output 1 ... 150 mA

Mechanical values and environment

Connection type Plug connector M23, 19-pin
Tightening torque
Fixing screws 4 Nm
Ready delay 12 s
Installation orientation any
Adhesive force
adjustable 0, ca. 30, ca. 50 (Auslieferungszustand 50 N) N
Mechanical life
in case of use as door stop, and 1 Joule impact energy 1 x 10⁶
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65/IP67 (screwed tight with the corresponding mating connector)
Ambient temperature -20 ... +55 °C
Material
Solenoid Steel, nickel plated
Read head Plastic (PBT)
Housing Aluminum
Locking force Fmax
in axial direction 600 N (The device signals if the locking force drops below 400N.)

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y
Monitoring of the guard position
Category 4
Performance Level PL e
PFHD 4.5 x 10-9

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 4,8 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 113739
Item designation CEM-I2-AR-M-C40-SH-113739
Gross weight 0,779kg
Customs tariff number 85365019000
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com