EUCHNER – More than safety.
EUCHNER – More than safety.

MSC-CE-SPM2H-121304 (Order no. 121304)

Expansion module MSC-CE

  • Input expansion
  • Speed monitoring for up to 2 axes
  • 2 inputs for proximity switch
  • 2 inputs for HTL encoder
  • Compact housing with width of only 22.5mm
  • Simple diagnostics via LED displays
  • Plug-in screw terminals
MSC-CE-SPM2H-121304 (Order no. 121304)

Description

Speed Control

This module enables the following safe monitoring of up to 2 independent axes. Up to 4 limit ranges can be configured for each axis.

  • Standstill

  • Overspeed

  • Speed ranges

  • Direction of motion (rotary motion/linear motion)

Inputs

  • 2 safe inputs for proximity switches with an input frequency up to 5 kHz

  • 2 safe inputs for HTL encoders with an input frequency up to 300 kHz

Scope of delivery

  • The expansion plug (order no. 121308) is included with the expansion module

Accessories

  • Plug-in screw terminals (order no. 121320) must be ordered separately

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
MSC: Safe control system MSC

Dimensional drawings

Dimensional drawings
1Page A
2Page B

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20TUEV Süd München_Z10 040393 0030 Rev.01c_UL_us_E353660_UL_us_E467239

Electrical connection values

Connection cross section 0.5 ... 2.5 mm² (Screw terminal)
Operating voltage DC
UB 24 V DC -20% ... +20% PELV (according to EN 60204-1)
Inputs
NumberTypeFunctionFootnote
2HTLEncoder
Overvoltage category according to IEC EN 60664-1 II
Power dissipation max. 3 W
Degree of contamination according to EN 60664-1 2
Proximity switch
Spacing limits min. 5 %
Number 2
Input type PNP / NPN 3/4-wires
Frequency max. 5 kHz
Frequency spacing min. 10 Hz
Limit range 1 Hz- 4 kHz (Configurable)
Encoder
Number 1
Frequency max. 300 kHz
Rated insulation voltage Ui 250 V
Rated surge voltage according to IEC 60664-1 4000 V
Limit range 1Hz - 450kHz (Configurable)

Mechanical values and environment

Dimensions 108 x 22.5 x 114.5 (Including screw terminals)
Storage temperature -20 ... +85 °C
Cable length max. 100 m
Atmospheric humidity 10 ... 95 % rH
Mounting type 35 mm mounting rail (according to EN 60715)
Degree of protection IP20
Ambient temperature -10 ... +55 °C
Material
Housing Polyamide
Proximity switch
Connection type Plug-in terminal (Terminal not included)
Number of axes 2
Encoder
Connection type RJ45
Number of axes 2

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y (according to ISO 13849-1:2008 / EN 62061:2005)
Category 4 (according to ISO 13849-1:2008 / EN 62061:2005)
Performance Level PL e (according to ISO 13849-1:2008 / EN 62061:2005)
PFHD 8.92E-09 1/h (according to IEC 61508:2010)

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 58,9 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 121304
Item designation MSC-CE-SPM2H-121304
Gross weight 0,235kg
Customs tariff number 85364110
ECLASS 27-24-22-05 SPS-Funktions-/Technologie-Modul