EUCHNER – More than safety.
EUCHNER – More than safety.

TP6-4120A024M (Order no. 084280)

Safety switch TP with door unlock request contact

  • Auxiliary shutdown feature on the front
  • With door unlock request contact
  • Increased horizontal overtravel
TP6-4120A024M (Order no. 084280)

Description

Approach direction

Horizontal and vertical

Can be adjusted in 90° steps

Increased overtravel for horizontal approach direction

Solenoid operating voltage

  • AC/DC 24 V +10%, -15%

Guard locking type

TP6

Open-circuit current principle, guard locking by applying voltage to the guard locking solenoid. Release by spring force.

Switching element

4120

Slow-action switching contact 1 NC (door unlock request contact) + 1 NC + 1 NO (solenoid monitoring contact)

Auxiliary shutdown feature

When actuated, positively driven contacts 21-22 are opened. The guard remains locked. The auxiliary shutdown feature must be sealed to prevent tampering (for example with sealing lacquer).

Door unlock request contact

When the actuator is in the locked state, positively driven contact 21-22 is opened by pulling the guard (6 mm actuator stroke). This forwards a signal to the higher-level PLC. Depending on the control concept, the guard can be unlocked automatically when machine components that were still running have stopped.

Switching function
Switching function
Dimension drawing
Dimension drawing
Wiring diagram 4120
Wiring diagram 4120
Electromechanical safety switches in use

Functional drawings

Functional drawings

Dimensional drawings

Dimensional drawings
1Auxiliary release
2Locking screw

Connection examples

Connection examples
Door unlock request
Solenoid monitoring

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_2/1CCC_2020980305000541_CQC2008010305306207DGUV_ET 20002_ET 20003

Electrical connection values

Power consumption 8 W
Connection cross section 0.34 ... 1.5 mm²
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2.5 kV
Utilization category
DC-13 4 A 24 V
AC-15 4 A 230 V
Short circuit protection according to IEC 60269-1 4A gG
Solenoid operating voltage
AC/DC 24 V -15% ... +10%
Solenoid duty cycle 100 %
Switching voltage
min. at 10 mA 12 V
Switching current
min. at 24 V 1 mA
thermal rated current Ith 4 A

Mechanical values and environment

Approach speed max. 20 m/min
Connection type
3 x M20 x 1.5
Number of guard lock monitoring NO contacts 1
Number of guard lock monitoring positively driven contacts 1
Extraction force 20 N
Actuation frequency max. 1200 1/h
Actuating force 10 N
Installation orientation any
Mechanical life 0.5 x 10⁶
Retention force 10 N
Switching principle Slow-action switching contact
Degree of protection IP67
Ambient temperature -20 ... +55 °C
Material
Housing Reinforced thermoplastic
Contact Silver alloy, gold flashed
Locking force Fmax 800 N
Locking force FZh 600 N

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

B10DMission time
Monitoring of guard locking3x10620 y
Important! Values valid at DC-13 100 mA/24V


In combination with actuator ACTUATOR-P-GNT

Horizontal overtravel 7 mm

In combination with actuator ACTUATOR-P-GT

Horizontal overtravel 2 mm
Vertical overtravel 1.5 mm

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 6,4 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 084280
Item designation TP6-4120A024M
Gross weight 0,452kg
Customs tariff number 85365019000
ECLASS 27-27-26-03 Safety switch with guard control