BP/BR safety switch with guard locking
Benefits for you
- Communicating safety switch with guard locking and safe guard lock monitoring
- Industry 4.0 ready
- Safety category 4 and PL e according to EN ISO 13849-1
Industry 4.0 ready
Switches from system families BP and BR can communicate in combination with an EUCHNER IO-Link Gateway, and send process and device data to higher-level control systems. Comprehensive diagnostic messages enable rapid and targeted troubleshooting.
Diagnostic information
The safety switches in this group can forward comprehensive diagnostic information to the control system. The devices supply process-relevant parameters in real time. They even provide information on preventive maintenance. The sensors measure relevant parameters in the surroundings to indicate problems before a machine failure can occur. In combination with the IO-Link Gateways GWY-CB and ESM-CB, this information is polled from every switch and provided to the control system via IO-Link.Products (35)
No results found

166702
CTA-L1-BP-U-HA-AP-SA-166702
Transponder-coded safety switch CTA-BP, M12
CTA-L1-BP-U-HA-AP-SA-166702
Transponder-coded safety switch CTA-BP, M12
- Safety switch with guard locking and integrated evaluation electronics
- Communication-capable in combination with IO-Link gateway GWY-CB or ESM-CB
- Cross-circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Closed-circuit current principle
- Up to category 4 / PL e according to EN ISO 13849-1
- With plug connector M12
- Unicode
- Door monitoring output
- Approach direction A, B and C (delivery state)

165454
CTA-L1-BP-U-HA-AP-SII-165454
Transponder-coded safety switch CTA-BP, 2 x M12
CTA-L1-BP-U-HA-AP-SII-165454
Transponder-coded safety switch CTA-BP, 2 x M12
- Safety switch with guard locking and integrated evaluation electronics
- Direct connection to decentralized peripheral systems (e.g. ET200pro)
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Closed-circuit current principle
- Up to category 4 / PL e according to EN ISO 13849-1
- With 2 plug connectors M12
- Unicode
- Door monitoring output
- Approach directions A, B and C (delivery state)

170930
CTA-L1-BP-U-HA-AP-SII-170930
Transponder-coded safety switch CTA-BP, 2 x M12
CTA-L1-BP-U-HA-AP-SII-170930
Transponder-coded safety switch CTA-BP, 2 x M12
- Safety switch with guard locking and integrated evaluation electronics
- Direct connection to decentralized peripheral systems (e.g. ET200pro)
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Closed-circuit current principle
- Up to category 4 / PL e according to EN ISO 13849-1
- With 2 plug connectors M12
- Unicode
- Door monitoring output
- Approach directions A, B and C (delivery state)

166653
CTA-L1-BR-U-HA-AP-SAB-166653
Transponder-coded safety switch CTA-BR, 2 x M12
CTA-L1-BR-U-HA-AP-SAB-166653
Transponder-coded safety switch CTA-BR, 2 x M12
- Safety switch with guard locking and integrated evaluation electronics
- Up to 20 switches in series
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Closed-circuit current principle
- Up to category 4 / PL e according to EN ISO 13849-1
- With plug connector 2 x M12
- Unicode
- Door monitoring output
- Approach directions A, B and C (delivery state)

166257
CTA-L1-BR-U-HA-AP-SH-166257
Transponder-coded safety switch CTA-BR, M23
CTA-L1-BR-U-HA-AP-SH-166257
Transponder-coded safety switch CTA-BR, M23
- Safety switch with guard locking and integrated evaluation electronics
- Series connection possible
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Closed-circuit current principle
- Up to category 4 / PL e according to EN ISO 13849-1
- With plug connector M23
- Unicode
- Door monitoring output
- Approach directions A, B and C (delivery state)

170659
CTA-L2-BP-U-HA-AP-SA-170659
Transponder-coded safety switch CTA-BP, M12
CTA-L2-BP-U-HA-AP-SA-170659
Transponder-coded safety switch CTA-BP, M12
- Safety switch with guard locking and integrated evaluation electronics
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Open-circuit current principle
- Up to category 4/PL e according to EN ISO 13849-1
- With plug connector M12
- Unicode
- Door monitoring output
- Approach directions A, B and C (delivery state)

166701
CTA-L2-BR-U-HA-AP-SAB-166701
Transponder-coded safety switch CTA-BR, 2 x M12
CTA-L2-BR-U-HA-AP-SAB-166701
Transponder-coded safety switch CTA-BR, 2 x M12
- Safety switch with guard locking and integrated evaluation electronics
- Up to 20 switches in series
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Open-circuit current principle
- Up to category 4 / PL e according to EN ISO 13849-1
- With 2 plug connectors M12
- Unicode
- Door monitoring output
- Approach directions A, B and C (delivery state)

170491
CTM-C2-BP-HC-FLX-AZ-SA-170491
Transponder-coded safety switch CTM-CBI-BP, M12
CTM-C2-BP-HC-FLX-AZ-SA-170491
Transponder-coded safety switch CTM-CBI-BP, M12
- Safety switch with guard locking and integrated evaluation electronics
- Communication-capable in combination with IO-Link gateway GWY-CB or ESM-CB
- Cross-circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Open-circuit current principle
- Category 4 / PL e according to EN ISO 13849-1
- Actuating force 20 N
- Withdrawal force 18 N
- Retention force 5 N
- Plug connector M12, 8-pin
- Auxiliary release
- Highly coded
- FlexFunction device

170490
CTM-CBI-BP-HC-FLX-AZ-SA-170490
Transponder-coded safety switch CTM-CBI-BP, M12
CTM-CBI-BP-HC-FLX-AZ-SA-170490
Transponder-coded safety switch CTM-CBI-BP, M12
- Safety switch with guard locking and integrated evaluation electronics
- Communication-capable in combination with IO-Link gateway GWY-CB or ESM-CB
- Cross-circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuating force 20 N
- Withdrawal force 18 N
- Retention force 5 N
- Plug connector M12, 8-pin
- Auxiliary release
- Highly coded
- FlexFunction device

168250
CTM-I2-BR-U-AZ-SA-168250
Transponder-coded safety switch CTM-I2-BR, M12
CTM-I2-BR-U-AZ-SA-168250
Transponder-coded safety switch CTM-I2-BR, M12
- Safety switch with guard locking and integrated evaluation electronics
- Guard locking only suitable for process protection
- Series connection possible
- Communication capable in combination with IO-Link Gateway GWY-CB or ESM-CB
- Cross-circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Open-circuit current principle
- Category 4 / PL e according to EN ISO 13849-1
- Actuating force 20 N
- Pull-out force 18 N
- Retention force 5 N
- M12 plug connector, 8-pin
- Auxiliary release
- Unicode

168251
CTM-I2-BR-U-AZ-SA-168251
Transponder-coded safety switch CTM-I2-BR, M12
CTM-I2-BR-U-AZ-SA-168251
Transponder-coded safety switch CTM-I2-BR, M12
- Safety switch with guard locking and integrated evaluation electronics
- Guard locking only suitable for process protection
- Series connection possible
- Communication capable in combination with IO-Link Gateway GWY-CB or ESM-CB
- Cross-circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Open-circuit current principle
- Category 4 / PL e according to EN ISO 13849-1
- Actuating force 20 N
- Pull-out force 18 N
- Retention force 5 N
- M12 plug connector, 8-pin
- Auxiliary release
- Unicode

166870
CTM-L2-BR-M-AZ-SA-166870
Transponder-coded safety switch CTM-L2-BR, M12
CTM-L2-BR-M-AZ-SA-166870
Transponder-coded safety switch CTM-L2-BR, M12
- Safety switch with guard locking and integrated evaluation electronics
- Series connection possible
- Communication-capable in combination with IO-Link gateway GWY-CB or ESM-CB
- Cross-circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Open-circuit current principle
- Category 4 / PL e according to EN ISO 13849-1
- Actuating force 35 N
- Withdrawal force 30 N
- Retention force 15 N
- Plug connector M12, 8-pin
- Auxiliary release
- Multicode

167789
CTM-L2-BR-M-ZZ-SA-P-167789
Transponder-coded safety switch CTM-L2-BR, M12
CTM-L2-BR-M-ZZ-SA-P-167789
Transponder-coded safety switch CTM-L2-BR, M12
- Safety switch with guard locking and integrated evaluation electronics
- Series connection possible
- Communication-capable in combination with IO-Link gateway GWY-CB or ESM-CB
- Cross-circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Open-circuit current principle
- Category 4 / PL e according to EN ISO 13849-1
- Actuating force 35 N
- Withdrawal force 30 N
- Retention force 15 N
- Plug connector M12, 8-pin
- Multicode
- Hygienic variant

168866
CTM-L2-BR-U-AZ-SA-168866
Transponder-coded safety switch CTM-L2-BR, M12
CTM-L2-BR-U-AZ-SA-168866
Transponder-coded safety switch CTM-L2-BR, M12
- Safety switch with guard locking and integrated evaluation electronics
- Series connection possible
- Communication-capable in combination with IO-Link gateway GWY-CB or ESM-CB
- Cross-circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Open-circuit current principle
- Category 4 / PL e according to EN ISO 13849-1
- Actuating force 35 N
- Withdrawal force 30 N
- Retention force 15 N
- Plug connector M12, 8-pin
- Auxiliary release
- Unicode

166088
CTM-LBI-BP-M-AZ-SA-166088
Transponder-coded safety switch CTM-LBI-BP, M12
CTM-LBI-BP-M-AZ-SA-166088
Transponder-coded safety switch CTM-LBI-BP, M12
- Safety switch with guard locking and integrated evaluation electronics
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuating force 26 N
- Extraction force 18 N
- Plug connector M12, 8-pin
- Auxiliary release
- Multicode

166090
CTM-LBI-BP-M-AZ-SA-166090
Transponder-coded safety switch CTM-LBI-BP, M12
CTM-LBI-BP-M-AZ-SA-166090
Transponder-coded safety switch CTM-LBI-BP, M12
- Safety switch with guard locking and integrated evaluation electronics
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuating force 26 N
- Extraction force 18 N
- Plug connector M12, 8-pin
- Auxiliary release
- Multicode

166087
CTM-LBI-BP-U-AZ-SA-166087
Transponder-coded safety switch CTM-LBI-BP, M12
CTM-LBI-BP-U-AZ-SA-166087
Transponder-coded safety switch CTM-LBI-BP, M12
- Safety switch with guard locking and integrated evaluation electronics
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuating force 26 N
- Extraction force 18 N
- Plug connector M12, 8-pin
- Auxiliary release
- Unicode

166089
CTM-LBI-BP-U-AZ-SA-166089
Transponder-coded safety switch CTM-LBI-BP, M12
CTM-LBI-BP-U-AZ-SA-166089
Transponder-coded safety switch CTM-LBI-BP, M12
- Safety switch with guard locking and integrated evaluation electronics
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuating force 26 N
- Extraction force 18 N
- Plug connector M12, 8-pin
- Auxiliary release
- Unicode

165517
CTM-LBI-BR-M-AZ-SA-165517
Transponder-coded safety switch CTM-LBI-BR, M12
CTM-LBI-BR-M-AZ-SA-165517
Transponder-coded safety switch CTM-LBI-BR, M12
- Safety switch with guard locking and integrated evaluation electronics
- Series connection possible
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuating force 26 N
- Extraction force 18 N
- Plug connector M12, 8-pin
- Auxiliary release
- Multicode

166588
CTM-LBI-BR-M-AZ-SA-166588
Transponder-coded safety switch CTM-LBI-BR, M12
CTM-LBI-BR-M-AZ-SA-166588
Transponder-coded safety switch CTM-LBI-BR, M12
- Safety switch with guard locking and integrated evaluation electronics
- Series connection possible
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuating force 44 N
- Extraction force 32 N
- Plug connector M12, 8-pin
- Auxiliary release
- Multicode

166092
CTM-LBI-BR-M-AZ-SP-166092
Transponder-coded safety switch CTM-LBI-BR, M12
CTM-LBI-BR-M-AZ-SP-166092
Transponder-coded safety switch CTM-LBI-BR, M12
- Safety switch with guard locking and integrated evaluation electronics
- Series connection possible
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuating force 26 N
- Extraction force 18 N
- Plug connector M12, 12-pin
- Auxiliary release
- Multicode

168651
CTM-LBI-BR-M-ZZ-SA-P-168651
Transponder-coded safety switch CTM-LBI-BR, M12, hygienic version
CTM-LBI-BR-M-ZZ-SA-P-168651
Transponder-coded safety switch CTM-LBI-BR, M12, hygienic version
- Safety switch with guard locking and integrated evaluation electronics
- Series connection possible
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuating force 44 N
- Extraction force 32 N
- Plug connector M12, 8-pin
- Unicode
- Hygienic version

161638
CTM-LBI-BR-U-AZ-SA-161638
Transponder-coded safety switch CTM-LBI-BR, M12
CTM-LBI-BR-U-AZ-SA-161638
Transponder-coded safety switch CTM-LBI-BR, M12
- Safety switch with guard locking and integrated evaluation electronics
- Series connection possible
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Bistable guard locking
- Category 4/PL e according to EN ISO 13849-1
- Actuating force 44 N
- Extraction force 32 N
- Plug connector M12, 8-pin
- Auxiliary release
- Unicode

161639
CTM-LBI-BR-U-AZ-SA-161639
Transponder-coded safety switch CTM-LBI-BR, M12
CTM-LBI-BR-U-AZ-SA-161639
Transponder-coded safety switch CTM-LBI-BR, M12
- Safety switch with guard locking and integrated evaluation electronics
- Series connection possible
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuating force 26 N
- Extraction force 18 N
- Plug connector M12, 8-pin
- Auxiliary release
- Unicode

167795
CTM-LBI-BR-U-AZ-SA-167795
Transponder-coded safety switch CTM-LBI-BR, M12
CTM-LBI-BR-U-AZ-SA-167795
Transponder-coded safety switch CTM-LBI-BR, M12
- Safety switch with guard locking and integrated evaluation electronics
- Series connection possible
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Bistable guard locking
- Category 4/PL e according to EN ISO 13849-1
- Actuating force 44 N
- Extraction force 32 N
- Plug connector M12, 8-pin
- Auxiliary release
- Unicode

166091
CTM-LBI-BR-U-AZ-SP-166091
Transponder-coded safety switch CTM-LBI-BR, M12
CTM-LBI-BR-U-AZ-SP-166091
Transponder-coded safety switch CTM-LBI-BR, M12
- Safety switch with guard locking and integrated evaluation electronics
- Series connection possible
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuating force 26 N
- Extraction force 18 N
- Plug connector M12, 12-pin
- Auxiliary release
- Unicode

161496
CTM-LBI-BR-U-ZZ-SA-P-161496
Transponder-coded safety switch CTM-LBI-BR, M12, hygienic version
CTM-LBI-BR-U-ZZ-SA-P-161496
Transponder-coded safety switch CTM-LBI-BR, M12, hygienic version
- Safety switch with guard locking and integrated evaluation electronics
- Series connection possible
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuating force 44 N
- Extraction force 32 N
- Plug connector M12, 8-pin
- Unicode
- Hygienic version

161640
CTM-LBI-BR-U-ZZ-SA-P-161640
Transponder-coded safety switch CTM-LBI-BR, M12, hygienic version
CTM-LBI-BR-U-ZZ-SA-P-161640
Transponder-coded safety switch CTM-LBI-BR, M12, hygienic version
- Safety switch with guard locking and integrated evaluation electronics
- Series connection possible
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuating force 26 N
- Extraction force 18 N
- Plug connector M12, 8-pin
- Unicode
- Hygienic version

167917
CTS-C1-BP-CC-FLX-AP-VSA-167917
Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12
CTS-C1-BP-CC-FLX-AP-VSA-167917
Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12
- Safety switch with guard locking and integrated evaluation electronics
- Up to category 4 / PL e according to EN ISO 13849-1
- 2 safety outputs (semiconductor outputs)
- Closed-circuit current principle
- Connection cable, PVC, 25 cm, plug connector(s) M12, 8-pin
- Auxiliary release on front and rear side
- FlexFunction device
- Communication-capable in combination with IO-Link gateway GWY-CB or ESM-CB
- Monitoring outputs OL and OD

169052
CTS-C1-BP-CC-FLX-AP-VSA-169052
Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12
CTS-C1-BP-CC-FLX-AP-VSA-169052
Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12
- Safety switch with guard locking and integrated evaluation electronics
- Up to category 4 / PL e according to EN ISO 13849-1
- 2 safety outputs (semiconductor outputs)
- Closed-circuit current principle
- Connection cable, PVC 25 cm, plug connector(s) M12, 8-pin
- Auxiliary release on front and rear side
- FlexFunction device
- Communication-capable in combination with IO-Link gateway GWY-CB or ESM-CB
- Monitoring outputs OD/OL and OER

171593
CTS-C1-BP-CC-FLX-AP-VSA-171593
Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12
CTS-C1-BP-CC-FLX-AP-VSA-171593
Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12
- Safety switch with guard locking and integrated evaluation electronics
- Up to category 4 / PL e according to EN ISO 13849-1
- 2 safety outputs (semiconductor outputs)
- Closed-circuit current principle
- Connection cable, PVC, 25 cm, plug connector(s) M12, 8-pin
- Auxiliary release on front and rear side
- FlexFunction device
- Communication-capable in combination with IO-Link gateway GWY-CB or ESM-CB
- Monitoring outputs OL and OT

169053
CTS-C1-BR-CC-FLX-AP-V05-169053
Transponder-coded safety switch CTS-C1-BR with FlexFunction, connection cable with open cable end
CTS-C1-BR-CC-FLX-AP-V05-169053
Transponder-coded safety switch CTS-C1-BR with FlexFunction, connection cable with open cable end
- Safety switch with guard locking and integrated evaluation electronics
- Up to 20 switches in series
- Up to category 4 / PL e in accordance with EN ISO 13849-1
- 2 safety outputs (semiconductor outputs)
- Closed-circuit current principle
- Connection cable, PVC, 5 m, flying lead
- Auxiliary release on front and rear side
- FlexFunction device
- Communication capability in combination with IO-Link gateway GWY-CB or ESM-CB
- Monitoring outputs OL and OD

169612
CTS-C1-BR-CC-FLX-AP-VAB-169612
Transponder-coded safety switch CTS-C1-BR with FlexFunction, 2 x M12
CTS-C1-BR-CC-FLX-AP-VAB-169612
Transponder-coded safety switch CTS-C1-BR with FlexFunction, 2 x M12
- Safety switch with guard locking and integrated evaluation electronics
- Up to 20 switches in series
- Up to category 4 / PL e according to EN ISO 13849-1
- 2 safety outputs (semiconductor outputs)
- Closed-circuit current principle
- Connection cable, PVC, 25 cm, plug connector(s) 2 x M12
- Auxiliary release on front and rear side
- FlexFunction device
- Communication capability in combination with IO-Link gateway GWY-CB or ESM-CB
- Monitoring outputs OD/OL

169051
CTS-C2-BP-CC-FLX-AP-VSA-169051
Transponder-coded safety switch CTS-C2-BP with FlexFunction, M12
CTS-C2-BP-CC-FLX-AP-VSA-169051
Transponder-coded safety switch CTS-C2-BP with FlexFunction, M12
- Safety switch with guard locking and integrated evaluation electronics
- Guard locking only suitable for process protection
- Up to category 4 / PL e in accordance with EN ISO 13849-1
- 2 safety outputs (semiconductor outputs)
- Open-circuit current principle
- Connection cable, PVC, 25 cm, plug connector(s) M12, 8-pin
- Auxiliary release on front and rear side
- FlexFunction device
- Communication capable in combination with IO-Link gateway GWY-CB or ESM-CB
- Monitoring outputs OL and OD

169613
CTS-C2-BR-CC-FLX-AP-VAB-169613
Transponder-coded safety switch CTS-C2-BR with FlexFunction, 2 x M12
CTS-C2-BR-CC-FLX-AP-VAB-169613
Transponder-coded safety switch CTS-C2-BR with FlexFunction, 2 x M12
- Safety switch with guard locking and integrated evaluation electronics
- Guard locking only suitable for process protection
- Up to 20 switches in series
- Up to category 4 / PL e according to EN ISO 13849-1
- 2 safety outputs (semiconductor outputs)
- Open-circuit current principle
- Connection cable, PVC, 25 cm, plug connector(s) 2 x M12
- Auxiliary release on front and rear side
- FlexFunction device
- Communication capable in combination with IO-Link gateway GWY-CB or ESM-CB
- Monitoring outputs OD/OL