SFM-A02 AS-Interface Safety Monitor

View PDF Now

The ASi Bus is a reliable way to implement safety devices on a communication bus. It can also be used to reliably activate outputs, such as locking solenoids. Data from all connected devices is transmitted through a two-wire cable to a safety controller. This will turn off hazardous machine functions in the event of an unsafe condition. A Windows compatible software package is available for easy configuration, monitoring and diagnostics. Single and multiple bus interface modules are also available. Many Euchner products can be purchased with an ASi interface. This reduces the time for assembly, installation, testing and downtime. The SFM-A02 safety monitor is a dual-channel monitor with 4 safety contacts.

TYPICAL APPLICATIONS INCLUDE

Assembly lines, Material handling / storage retrieval systems, Packaging, Machine tool, Food processing, Robots, Petrol chemical processing, Pharmaceutical, Utilities, Waste management

 
 

FEATURES

  • Dual-channel
  • Stop category 0 and 1, door locking via time-delay or standstill monitor
  • Up to safety category 4 in accordance with EN 954-1
  • 4 safety contacts
  • Start input, automatic start, start via bus subscriber
  • Feedback loop for every channel
   

BENEFITS

  • Multiple connection options
  • Improved user interface
  • Safe output directly on the AS-Interface bus
  • Plug-in terminal
  • Diagnostics LED’s
   

TECHNICAL

  • Ambient temperature -20 to 60°C
  • Operating voltage 24VDC
  • Single-channel
  • 2 NO safety relay outputs
  • Signaling output
    • PNP transistor output
    • 200mA
    • Protected against short circuit and reverse polarity
  • External fusing: 4A medium slow-blow
 
 