Non-contact safety switches are interlocking devices that are designed to protect people and machines. Compared with electromechanical safety switches, they are used if: a high level of protection against tampering much be achieved, extremely hygienic environmental conditions are required (e.g. in the food industry), a precise door guide is not possible, machine doors are subjected to heavy vibration, a high safety category is stipulated during the risk analysis.

 
 

Coded Magnet switches

Non-contact safety switches that use coded magnets to close contacts.


CMS-E-AR, CMS-E-DR:


Non-contact systems that allow for the connection of a maximum of 30 read heads.

CMS-E-AR module can achieve safety category 3 using 1 to 2 read heads and safety category 2 using 3 to 30 read heads.

CMS-E-DR module can achieve safety category 2 using 1 to 2 read heads and safety category 1 using 3 to 30 read heads.


CMS-E-BR, CMS-E-ER, CMS-E-FR:


Non-contact systems that allow for up to 30 read heads to be attached. Have door monitoring and feedback capabilities.

CMS-E-BR module can achieve safety category 3 using 1 to 4 read heads.

CMS-E-ER module can achieve safety category 4 using 1 read head and safety category 3 using 2 to 30 read heads.

CMS-E-FR module can achieve safety category 4 using 1 read head and safety category 3 using 2 to 30 read heads. This module also has 6 monitoring outputs.


 

 

RFID Coded switches

Non-contact safety switches that use uniquely coded transponders to determine safe states.


CES-AR-AES-12


Evaluation unit allows for 12 read heads, Unicode or Multicode with individual switch status outputs


Unicode (Individual)


CES-AZ-AES-01B:


Evaluation unit allows for 1 read head and can achieve safety category 4.


CES-AZ-AES-02B:


Evaluation unit allows for 2 read heads and can achieve safety category 4.


CES-AZ-AES-04B:


Evaluation unit allows for 4 read heads and can achieve safety category 4.


Multicode (Universal)


CES-AZ-UES-01B:


Evaluation modules that allows for 1 read head and can achieve safety category 4.


CES-AZ-UES-02B:


Evaluation modules that allows for 2 read heads and can achieve safety category 4.


CES-AZ-UES-04B:


Evaluation modules that allows for 4 read heads and can achieve safety category 4.


 

 

Read head and Actuator:


CES read head and actuator:


Non-contact transponder coding read heads and actuators which are used in conjunction with the evaluation modules.


CES-A-LSP read head and actuator:


Non-contact transponder coding read heads and actuators the fit in extrusion which are used in conjunction with the evaluation modules.


Read heads with integrated evaluation:


CES-A-C5E and CES-A-C5H:


Read head with integrated evaluation. 2 safety outputs and 1 monitoring output are available.


CES-AR C:


Evaluation and read head in one that is suitable for systems on which a large number of safety doors need monitoring. Up to 20 safety switches can be connected in series.


CES-A-S5H:


Evaluation unit and read head in one housing with 2 safety outputs. 14 different position actuators and 1 safety actuator can be detected. 4 binary outputs indicate the actuator number.


CES-AH:


Read Head with integrated evaluation and high current outputs. Up to 4A can be switched directly.


CES-AP Safety Switch:


These systems feature an inductive read head with integrated evaluation unit and a digitally coded actuator.


Separate actuator with guard locking:


CEM:


Non-contact unit that has a digitally coded actuator with locking electromagnet built into housing. An evaluation unit is required to complete the system.


CEM with Adjustable Adhesive Force:


Non-contact unit that has a digitally coded actuator with adjustable electromagnet built into the read head housing. An evaluation unit is required to complete the system.


CET-AX:


Non-contact read head with guard locking and guard lock monitoring. An evaluation unit is required to complete the system.


CET-AR:


Features an inductive read head with integral evaluation unit, and a digitally coded actuator. Up to 20 safety switches can be connected in series.

 