Safety switches and non-contact switches, ESM-F Safety Module, Relay Modules

ESM-F Safety Module

View PDF Now

EUCHNER ESM-F Modular Safety System is an innovative design interconnecting safety modules and reliably turns off hazardous machine functions in the event of an unsafe condition. It will also ensure that the machine cannot be restarted until the unsafe condition is corrected and the module reset. This can be used to protect people, machinery and manufacturing processes. Up to safety category 4 (in accordance with EN954-1) and stop category 0 or 1 (in accordance with EN60204-1) can be achieved with the proper installation. The safety input modules are positioned to the left of the basic safety module and the safety output modules are placed on the right side.

TYPICAL APPLICATIONS INCLUDE

E-stop circuit, Time delay module (stored energy hazard, stop coasting or rotating machinery), Used with safety interlocks & non-contact coded magnet safety switches, Input modules for light curtains

 
 

FEATURES

  • Variety of safety relay modules available
  • 35mm DIN rail mounting with backside interconnection
  • Input modules
    • Single channel
    • Dual channel
    • Modules for light curtains
    • Modules for coded magnets
  • Output modules
    • Four safety output
    • Time delay output modules
      • 1 to 30 seconds delay
      • Fixed .5 second delay
  • Two wire GO input interconnection
  • Plug-in connection terminals
  • CE
  • UL applied
   

BENEFITS

  • Simple plug-in and use modular design
  • Flexible from basic module with your design changes
  • No programming
  • Interconnection of safety groups can switch up to 8 amps
  • Status LED's with inputs and outputs
  • As required by NFPA machine safety standard as required by EN954,EN60204-1
  • Variations of non-contact CMS read heads are available for use with safety relays
   

TECHNICAL

  • Variety of voltages available
    • 24 VAC/DC
    • 115 V
    • 230V
  • Automatic, manual, or monitored start selectable
  • Ground fault monitoring
  • Short circuit monitoring
  • Up to safety category 4
  • To stop category 0 or 1 power ON troubleshooting
 
 