Control units for safety photocells ILION and ULISSE, which can be combined to form a Type 2 safety system. Up to 4 photocells can be combined. Modules provide guided contact safety relays (2 N.O. contacts and PNP output for status signaling). The AUSSM provides for an additional Muting function. ILION or ULISSE photocells must be combined with AUSX or AUSXM control units to provide the specified safety level.
         


TYPICAL APPLICATIONS INCLUDE

For use with REER ILION or ULISSE photocells and light curtains for muting applications

FEATURES
  • 2-sensor Muting logic
  • Muting timeout selectable
    • 30 sec, 90 min or infinite
  • AUSX 3 LED diagnostic display
    • In1, In2/Fail, Guard Break
  • AUSXM 6 LED diagnostic display
    • S1, S2, Mut, In1, In2/fail, Guard Break
BENEFITS
  • Approved for Safety Category 2
  • Provides safety contacts
  • Connect up to 4 photocells
  • Reduces and simplifies safety circuit design
  • Easy installation and wiring
  • Quick status check with integral status output
TECHNICAL
  • General Specifications:
    • 35mm DIN mount
    • 22.5mm and 35mm wide modules
    • Environmental protection IP20
  • Ambient operating temperature 0 to 55C
  • 2 N.O. contacts rated 2A 250Vac
  • PNP Status output 100 mA
  • Operating voltage 24VDC +/- 20%
  • Power Dissipation 5 Watts
  • Type 2, SIL 2, SILCL 2, Cat2/PLd