JANUS, Optoelectronic Safety Barrier for the protection of workers exposed to risks arising from the use of dangerous machines, in situations where the MUTING function is necessary. The Safety Barrier Janus, with its two safe static outputs, can work without external control units having all safety functions integrated inside the Emitter and the Receiver and complying with the requirements of European Standard EN 61496-1 and International Standard IEC 61496-1-2.



Palletizers, robotized areas, assembly lines, automatic industrial warehouses and areas where AGV automatically guided vehicles pass

Janus muting presentation video

  • Protected height range from 310 to 1810mm
  • Multiple detection types
    • 30-40mm resolution
    • 90mm resolution
    • 2-3-4 beam for body detection
  • Maximum range
    • 16 or 60 meters(MI)
    • 2.5 meters (ML & ML)
  • Setup through main controller
  • Self-monitoring static outputs
  • Automatic or manual Start / Restart
  • Built-in muting
  • Muting time-out 30s, 90m, or infinite
  • Achieves the highest level of safety
    • Approved for Safety Category 4
  • East to install
  • Setup done without computer
  • Muting allows passing of product while maintaining operator protection.
  • Complies with muting geometry parameters per IEC TS 62046
  • Interfaces with MJB box or AD SR1 module
  • General Specifications:
    • 50x60mm housing cross section
    • Environmental protection IP65
  • Ambient operating temperature -10 to 55C
  • 2 safety PNP auto-controlled outputs rated 500mA
  • 1 PNP Status output rated 100mA
  • M12 and M23 connectors
  • Operating voltage 24VDC +/- 20%
  • Power consumption:
    • Emitter 3 Watt
    • Receiver 6 Watts
  • Type 4, SIL 3, SILCL 3, Cat4/PLe